Power SYSTEMsPower SYSTEMs
Trình bày:
Nguyễn Văn Hòa
ContentContent
� Gamatronic Overview
� Power+ UPS Systems
2
� Mega V2 Modular UPS Systems
� DC Power System
� 1970 - Gamatronic was founded by Mr. Joseph Goren
� 1994 - Gamatronic became a public company and traded on the Tel Aviv Stock
Exchange.
IntroductionIntroduction
3
� Gamatronic began manufacturing modular solutions for Telecom power systems in
1996
� 2001 - Gamatronic established a daughter company in UK
� 2004 - Gamatronic established an rep office in China
� 2006 - Gamatronic established an rep office in Brazil
� Gamatronic is a main supplier for Bezeq – the Israeli Telecom and approved supplier for the cellular operators in Israel.
� Orange (Partner), Cellcom, Pelephone, Mirs
� Global Telecom projects are installed in Africa, EMEA, South America, Asia and Far East
Full product power supplies range developed in-
house:
� UPS Systems
� Telecom Power systems
� DC/AC inverters
4
� DC/AC inverters
� DC/DC Converters
� STSW Modules
� FRNC/ Frequency Converters
� Control & Management solutions
� Customize Solutions
5
6
Power+ UPS family
7
Mega V2 UPS family
Power+ & Mega Power+ UPS family
� Power+ SA (Stand-Alone)
� 10kVA 400v
� 30, 40Kva
� Power+ 19”
� 10kVA
� 20kVA
� Power+ Premium, Classic and Freestyle
� Up to 50kVA
� Up to 100kVA
� Power + RM 10-(50)-100Kva
� 10 – 50 – 100 Kva
� Mega V2 Modular UPS
� 25-250Kva
� 25-500Kva8
Main Power+ features
� Double conversion UPS
� On-line batteries
� DC link
� Centralized batteries
� Centralized ST/SW
� Hybrid ST/SW topology� Hybrid ST/SW topology
� SNMP/WEB communication
9
� 10kVA / 8kW modules
� Module weight is 9kg
� 3/3, 3/1 or 1/1 phase operation
� Very quiet operation
� Modular housing
� Hot-swappable modules
� Hot-swappable controller
Green Power
Green power features:
� 3-5% THDi
� Unity power factor
� 96% AC/AC efficiency
� 98% DC/AC efficiency
� Lowers dissipation
� 2% Output THD
10
Results:
Environmental friendly
Lowers data center cooling expenses
Money savings on electric bills
Low generator oversizing (~1 to 1.2)
No network interference
Less pollution and fuel consumption
9 failures of power affect to IT device
� Power failure
� Power Surge
� Power Sag
� Overvoltage� Overvoltage
� Undervotage
� Switching Transients
� Electrical Line Noise
� Frequency Variation
� Harmonic Distortion
11
Double Conversion UPS
12
Double Conversion UPS performs
dual conversion of power, providing
protection against most main power
related issues.
UPS module
13InverterRectifier
Off-Line battery
Many manufacturers use the off-line battery topology.
~=
=~
DC link
PFC
rectifier
Transformerless
PWM inverter
AC input AC output~=
=~
DC link
PFC
rectifier
Transformerless
PWM inverter
AC input AC output
14
Battery
==~
=
Battery
chargerBattery
DC/DC
Booster
Battery
==~
=
Battery
chargerBattery
DC/DC
Booster
• Complicated
• Less reliable
• Not suitable for long backup times
On-Line Battery
15
On-Line battery lets the UPS
operate during power failures
without switching, since the battery
is linked directly to the DC bus.
De-centralized battery
De-centralized battery system in some well-known UPS
16
Centralized battery
Centralized battery of Power+ UPS family
17
Battery cabinets
� In most cases the battery cabinets are external.
Nevertheless, internal hot-swap battery cabinets for low
capacities are available as well:
64/60 x 20AH/12V
18
64/60 x 20AH/12V
64/60 x 5AH/12V
Static Switch
Distributed Static Switch:
� In this case, each UPS module has got its own internal static
switch
� Outputs of all modules are linked together and are wired
directly to the load19
Static Switch (cont..)
Centralized Static Switch:
� When implementing centralized topology, outputs from all
modules are linked together to the “inverter” input of the static
switch module.
� There is one device that handles the inverter / bypass switching20
System Controller
Navigation andLCD Panel
21
Network Access Indicator
Navigation and
Operation keypad Status indicatorsOperation buttons
LCD Panel
System ControllerPC575 is the WEB interface board:
� Network adaptor is a standard
feature of the System Controller
� Remote control features cover all
possible options:
� SNMP communication
� Web interface
The IP address can be configured on the
System Controller or through the network.
22
� Emergency power off
(EPO)
� SMS alarm notifications
(with optional WING
device)
� Remote monitoring panel
Redundancy
+
23
+
6 modules for 50k
N+1 redundant system
Two complete 50k units
for N+1 redundancy
The modular design of Power+ UPS provides a cost effective redundancy
with higher efficiency than conventional parallel UPS systems.
General functional diagram
24
Lower TCO & increase ROI:
� SAVE ON purchasing & installation costs
� SAVE ON electricity costs
� SAVE ON maintenance costs
� SAVE ON spacing costs
25
� SAVE ON spacing costs
� SAVE ON cooling costs
� SAVE ON upscaling costs
� SAVE ON generator costs
Power+ System
Premium,Classis, Freestyle, RM, SA, 19”
26
Power+ Classis 50 – 100Kva
� Controller:
Hot swap, 2U high, SNMP standard
� Housing:
Mechanical modular,
19” Rack
� Modules:
up to 10 modules
Each module 10kVA / 8kW
2U high / 9 kg (21lbs)
� Base Module:
27
� Base Module:
Up to 50KVA or 100KVA
AC Distribution Panel
DC Distribution panel
Input terminals
Battery terminals / Plugs
Space and wiring for the ST/SW module
Centralized Static Switch
Up to 50KVA or 100KVA
� All cables are included in a housing unit, for
any height
� An additional housing can be mounted on to
an existing unit
� Housings can hold UPS modules or System
Controllers
Power+ Free Style 50 – 100Kva
28
Power+ Rack mount 50 – 100Kva
29
Module UPS
10kVA/10kW
Controller
7" color touch screen
Power+ Premium 50 – 100Kva
� Same footprint with an effective
30
Static Switch
� Same footprint with an effective
increase of 25% in power output to 10kW
� Support output 10 kVA / 10 kW to 100
kVA / 100 kW
� Support 7" color touch screen
� User interface with 7 languages and
optional others
Power + 19”: 10/20kVA
Can be integrated as a sub rack
for any standard 19” rack, for a
lower cost of 10/20kVA UPS
One or two 10kVA Power +
modules
31
4U for
10kVA6U for
20kVA
Weight 19.9kg to 31.7kg for each type.
External battery cabinet.
A controller with a built-in STSW
� Power+ SA (Stand Alone/ Tower) 10KVA
� Stand-alone ON-LINE double-conversion UPS
� lightweight and compact design, weighing only 18Kg.
� Flexible use - available in 3/3, 3/1 and 1/1
High efficiency AC/AC: 96%
Low input THDi: <5%
Input PF: 1
Back light LCD
� Mainly used for Small & Medium size applications, as
well as OEM component for large devices (such as
Medical CT).
32
Medical CT).
� Not Available in Parallel. Doesn’t have P+ features ,
(temp compensation, Batt current limit).
� 384W power dissipation
64 x 5AH/12V
8 min at 100% load
25 min at 50% load
Recharge time 4-6hs
45 (H) x 26 (W) x 60 (D)
110kg
Battery cabinet
(External)
Power+ SA 20-40Kva
33
Mega V2 Modular
34
Mega V2 25-125Kva
35
LCD control panel LCD control panel
Mega V2 50 - 500Kva
36
Parallel Connection
37
Parallel Connection
For even more power and extra redundancy,Power+ can be put in parallel
de-centralized configuration. This will enable a combination of both vertical
and horizontal redundancy!
38
Toady there are dozens
of 200, 300, and 400kVA
systems worldwide,
supporting most critical
applications.
Parallel Connection
39
Parallel Connection
Parallel kit
location
40
� Since the parallel kit is being mounted at the rear, parallel
units are deeper than the Classic ones.
Parallel ConnectionParallel Connection
41
L1L1 L2L2 L3L3L1L1 L2L2 L3L3 L1L1 L2L2 L3L3
DC Power System
42
Solutions -Trends
• Telecom and Cellular solutions are based on a wide variety of
power requirements.
• Small sites require 100’s watts capacity, whereas medium sites
100-1000’s watts and large sites 10’s KW
Large SitesMedium SitesSmall sitesSites
75,100,20025,506,12,18Rectifiers
43
75,100,20025,506,12,18Rectifiers
Currents (A)
91%91%-92%90%Efficiency
DC power systemDC power system
Why do we use -48VDC in telecom equipment ?
• Positive voltages cause comparatively more corrosion inmetal than negative voltages.
• Negative voltages are safer for human body while doingTelecom activities.
• Lightning may cause positive voltages in the equipment• Lightning may cause positive voltages in the equipmentcircuitry. In that case, negative voltages (lack ofelectrons) neutralize positive charges and preventexcessive heat.
• Negative voltage is safer for long telephone line fortransmitting power trough it.
• The reason for electing -48V in reference to ground is toavoid the nasty galvanic effects in telephone cabling.+48V would have nastier effect on wet cabling.
DC power systemDC power system
User friendly:
-Light weight: 1,2kg/ module
-Hot swapped system controller
-USB or TCP/IP+USB communication
Efficiency:
-LLC tech to achieve efficiency 96%.
-Input PF=0.998, THD for input
voltage lower than 5%
Safety:
-Option to connect 2 external LVD
(Low voltage disconnect)
contactors up to 1600A.
Standard & Maximize system
capacity:
-19” 1U subrack that can house up to 3
hot-plugged rectifiers, or 2 rects +
controller and an LVD device.
-Reach 1266A with height of 13U ((38
recti ers + controller)).
DC power systemDC power system
� High efficiency Power systems up to
95%-96% - Reduction in energy costs
� Parallel 1UDC rectifiers are lower in cost
than high capacity single rectifiers- Reduction
in Price
� A larger quantity of rectifiers creates
singularity during the operation of the
system. Therefore the Power system
becomes more reliable and smaller in
footprint
DC power systemDC power system
Many new standards and industry goals are lead by
the goal to save energy and reduce greenhouse
gase emmissions.
� The 1UDC modules of Gamatronic increase
energy savings
� The product is more environmental friendly
� Lowers cooling expenses
� Lowers heat dissipation
� Less usage of space and storage
� Lower generator over sizing (~1 to 1.2)
� Less pollution and fuel consumption
DC power systemDC power system
Struture of DC Power source system
11U DCU DC + + rectifierrectifier
� Single phase input.
�Universal Input voltage , 90-270 Vac (with de-rating).
�Rectifier Output : 48 V/ 33.3 A.
�Active current sharing.
49
�Active current sharing.
� Short circuit protection.
� PFC (0.99).
�High power density: 1800 W in 146 mm (W) x 44 mm (H) x 260 mm (D).
�High efficiency - up to 95%-96 %.
11U DCU DC + + rectifierrectifier
�Hot swap plug-in rectifier.
�Digital bar graph for current measurements.
�Light weight – 1.2 kg .
�RS232 communication with controller.
50
�RS232 communication with controller.
�CE compliant.
�MTBF 250,000 hrs.
11U DCU DC + + ControllerController
51
Two types of controllers are available:
• SC 1UDC + : USB communication .
• SC 1UDC + NET : USB + TCP/IP / SNMP communication.
11U DCU DC + + controllercontroller
� 6 Dry contacts , programmable from a list of 32 alarms on site.
� FL + EQ charging mode .
�Rectifier voltage adjustment (in FL/EQ mode).
�EQ performance (automatic and manual).
52
�EQ performance (automatic and manual).
�Double e-LVD operation & low voltage adjustment.
�Battery test (automatic and manual).
�Battery current limiting.
�Temperature compensation.
�All alarm parameters are adjustable.
11U DCU DC + + controllercontroller
status indications:status indications:
� Input voltage.
� Dc voltage: rect., load & battery voltage.
� Current – rectifiers, batteries and load.
� 2 temp. measurements.
53
� 2 temp. measurements.
� Dc C.B. status (optional).
� LVD status.
� Battery status.
� Status of all voltages in the system.
� Event log of 256 most recent events.
Block diagram of the PSBlock diagram of the PS11UDC+ power system UDC+ power system
54
Communication with the Power SystemCommunication with the Power System
55
Thank you !Thank you !Thank you !Thank you !