D7024 COMPLETO ESPAÑOL
-
Upload
luisruizch -
Category
Documents
-
view
875 -
download
3
Transcript of D7024 COMPLETO ESPAÑOL
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
1ZVW2, 22.12.00
Department
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
2ZVW2, 22.12.00
Ver. 2.02 y superiores
Instalacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
3ZVW2, 22.12.00
Department
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
4ZVW2, 22.12.00
Propiedades Sistema Teclado LCD incorporado Hasta 4 teclados adicionales Hasta 8 anunciadores remotos adicionales Comunicador Doble Linea Incorporado 4 Puntos On-Board (Expandible a 8) 247 Direcciones Off-Board (para entradas y/o salidas) 16 Codigos Usuario (Expandible a 100) Numeros PIN 4 Digitos Niveles Autoridad Programables Buffer de Memoria 99 Eventos (Expandible a 499) Programacion Libre Display Alfanumerico Programacion Dirigida a traves de Menus Programable con RAM IV Aprobaciones UL, CSFM, MEA
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
5ZVW2, 22.12.00
Especificaciones Corriente
Entrada Corriente: 120 V, 60 Hz, 1.5 A
Corriente Notification Appliance Circuit (NAC): Cada NAC tiene 24 VDC nominal, corriente no filtrada
con hasta 2.5 A capacidad (4.0 A max.) Corriente Auxiliar:
24 VDC nominal, no filtrada, 1.0 A Corriente Circuito Iniciacion (Humo):
24 VDC nominal, filtrada, 1.0 A. Corriente Bus Option:
12 VDC nominal, 500 mA Baterias Opcionales Standby:
Dos 12 V (en serie), 7 – 40 Ah
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
6ZVW2, 22.12.00
Cont. Especificaciones Notification Appliance Circuits (NACs)
Dos circuitos notificacion on-board - NAC 1 y NAC 2. Cableado para estandares Class B, Estilo de operation Y
(use modelo de convertidor NACD7015 Clase B a Clase A para convertir a Clase A, Estilo Z como se necesita).
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
7ZVW2, 22.12.00
Department
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
8ZVW2, 22.12.00
Modulos
Panel de Incendio D7024
D7014 – Convertidor Zona Clase A
D7015 – Convertidor NAC
D7030 – Anunciador Remoto LED
D7031 – Keyswitch Remoto
D7033 – Teclado LCD
D7034 – Expansor 4 Puntos
D7035 – Modulo Relevo Remoto
D7036 – Teclado Anunciador Fuego
D7038 – Fuente Poder Remota NAC
D7039 – Modulo Expansion Multiplex
D7042 – Modulo 8 Entradas
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
9ZVW2, 22.12.00
Modulos–Convertidor Zona Clase A D7014
Panel de Incendio D7024
Convertidor Zona Clase “A”
Convierte un Clase “B” a Clase “A”
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
10ZVW2, 22.12.00
Modulos – Convertidor NAC D7015
Panel de Incendio D7024
Convierte Circuito NAC Clase “B” a circuito Clase “A”.
Compatible con circuitos NAC 24V
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
11ZVW2, 22.12.00
Modulos – Anunciador Remoto D7030
Panel de Incendio D7024
8 LED’s Personalizables
Indica Sitios Alarma
LED’s Corriente y Fallo
Cables cuatro hilos
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
12ZVW2, 22.12.00
Modulos – Teclado LCD D7033
Panel de Incendio D7024
Display Alfa/Numerico
2 Lineas, 32 Caracteres
Sistema Control Remoto
4 LED’s de Estado
Proteccion con clave
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
13ZVW2, 22.12.00
Modulos – Expansor Puntos D7034
Panel de Incendio D7024
Expansor 4 Puntos
Usa dispositivos N/O o N/C
Detectores 2 o 4 hilos
20 circuitos 2 hilos
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
14ZVW2, 22.12.00
Modulos – Modulo Relevo Remoto D7035
Panel de Incendio D7024
8 Salidas Forma “C”
Cada Relevo Programable
Hasta 2 Modulos/7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
15ZVW2, 22.12.00
Modulos – Teclado Anunciador Fuego D7036
Panel de Incendio D7024
Teclado/Anunc LCD.
2 Lineas/16 Carac./linea
Buzzer incorporado
Resetea Panel desp. Alarma
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
16ZVW2, 22.12.00
Modulos – Expansor Multiplex D7039
Panel de Incendio D7024
Modulo Expansor Puntos
2 Buses Mux Clase “B”
o
1 Bus Mux Clase “A”
Expande a 100 PIN’s
Expande Memoria a 499
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
17ZVW2, 22.12.00
Dispositivos Puntos Off-Board D7042 Modulo 8 Entradas
D7044(M)-Entrada Sencilla Direccionable /M = mini
D7050(TH)- Cabeza Humo Direccionable Photo-elect.
D7050B – Base 2 hilos 6’’ TH = 135f sensor seguro calor
D7045- Estacion Manual Direccionable
D7052- Entrada Doble Direccionable/Total 60
D7053- Entrada/Salida Direccionable [5a @ 28vdc]
(Total 40 (20 en cada lazo aislado clase b SLC)
(Relevo usa funciones programable sistema)
D243P- Cabeza Detectora Direccionable para Ductos con/D7050DH Total 70
D344-RT Plato Remoto Pruebas Total 40
D344-RL Anunciador Remoto LED Total 50
Primeros 10 puntos perdidos anuncian individualmente … si hay mas de 10 “Common Bus Failure”
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
18ZVW2, 22.12.00
Modulos – Modulo 8 Entradas D7042
Panel de Incendio D7024
8 Entradas Remotas Modulo Mux
8 Circuitos Iniciacion Clase “B”
Hasta 76 mt en Circuitos Iniciacion
Direccionable Dip Switch
Tamper w/bypass para pruebas
Address Sw.Tamper
Tamper Bypass
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
19ZVW2, 22.12.00
Modules – Fuente Poder Remota D7038
Panel de Incendio D7024
6 Amps de Corriente
4 Lazos Clase “B”
Salida Regulada 24VDC
Total/ Protegida/Supervisada
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
20ZVW2, 22.12.00
Department
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
21ZVW2, 22.12.00
D7024 Fire Alarm Control / Communicator
Instalacion y Puesta en Marcha
En la caja de envio, usted encontrara:
Un Control/Comunicador D7024 en paquete resistente estatica
Una Caja con transformador
Un paquete hardware
Una cerradura, anillo sujeccion, y llaves
Seis Resistencias Fin-de-Linea (EOL)
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
22ZVW2, 22.12.00
D7024 Fire Alarm Control / Communicator
Usando la base como plantilla, marque los hoyos de montaje
Pre-fije los tornillos montaje para estos dos hoyos.
Deslice la caja sobre estos tornillos
Aprete los tornillos.
Fije con dos tornillos los hoyos inferiores.
Quite las entradas deseadas de cable
Panel de Incendio D7024
Instalando la caja
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
23ZVW2, 22.12.00
D7024 Fire Alarm Control / Communicator
Instalando el Control/Communicator
Inserte los 3 postes soporte en los hoyos retenedores
Deslice la parte superior de la caja en los tabs.
Asegure las dos esquinas inferiores a traves de los hoyos retenedores
Conecte el cable de tierra inserto
Asegurese de tocar tierra antes de manipular la tarjeta controladora
Conecte la tierra de AC.
Panel de Incendio D7024
Presione los soportes de nylon 1/8" dentro de los hoyos retenedores
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
24ZVW2, 22.12.00
Cableado
Panel de Incendio D7024
120VAC xfmr
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
25ZVW2, 22.12.00
Terminales Funcion
1 NAC 1 + +24V en alarma; tierra mientras en standby
2 NAC 1 - Tierra en alarma; voltaje supervisado en
standby
3 NAC 2 + +24V en alarma; tierra mientras en standby
4 NAC 2 - Tierra en alarma; voltaje supervisado en
standby
5 Bateria -
6 Bateria +
Requires 2 12 V batteries in series; combinedvoltage 24 V; Charge Current 1.1 A max.
Todo el cableado exceptuando puntas bateria y entrada AC esta limitada por corriente.
Separar estos de otros cables por lo menos 1/4”, y asegurelos
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
26ZVW2, 22.12.00
Terminales Funcion
7 12 V + Bus A Option
8 Com Bus A Option
9 Data Data Bus A OptionBus A Option
10 Data Data Bus A Option [amarillo]Bus A Option [amarillo]
11 12 V + Bus B Option
12 Com Bus B Option
13 Data Data Bus B OptionBus B Option
14 Data Data Bus B Option [amarillo] Bus B Option [amarillo]
*Puede usar solamente un bus option al tiempo
D7024 InstallationPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
27ZVW2, 22.12.00
Terminales Funcion
21 Earth Ground
20 Loop 4 -
19 Loop +
18 Loop 3 -
17 Loop 2 -
16 Loop +
15 Loop 1 -
D7024 Installation
All EOL resistors 2.21k-ohmInitiating Devices Class B, Style B2-wire Compatibility Identifier “A”
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
28ZVW2, 22.12.00
Terminales Funcion
25 SMK + Corriente Humos 24 V, 1.0A max.
[filtrada]
24 SMK - Switchada Supervisada
23 AUX + Corriente Auxiliar 24 V, 1.0A [sin filtrar]
22 AUX - No switchada No Supervisada
D7024 InstallationPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
29ZVW2, 22.12.00
Terminales Funcion
31 NC 2
30 COM 2
29 NO 2
28 NC 1
27 COM 1
26 NO 1
D7024 Installation
Relay 2
Relay 1
For connection to listed power limited Class 2 orClass 3 sources only. Contacts rated at 5.0A, 28 V.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
30ZVW2, 22.12.00
Terminales Funcion
39 R 2
38 HR 2
37 HT 2
36 T 2
35 R 1
34 HR 1
33 HT 1
32 T 1
D7024 Installation
Phone 2
Phone 1
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
31ZVW2, 22.12.00
Expansion
Panel de Incendio D7024
D7034
•Expansor 4 Zonas
•Puntos On-Board
D7039
•Expansor Multiplex
•240 Puntos Off-Board
Modulo I/O
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
32ZVW2, 22.12.00
D7024 Fire Alarm Control / Communicator
Instalacion Equipo Opcional
Hay tres opciones de expansion que pueden conectarse directamente al panel
Expansor D7034 Cuatro Entradas
Expansor Multiplex D7039
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
33ZVW2, 22.12.00
D7024 Fire Alarm Control / Communicator
Instalacion Equipo Opcional cont.
Cuando el panel es re-energizado, el panel mostrara lo siguiente:
y/o
y/o
Presione la tecla [Clear] para confirmar la instalacion de los dispositivos
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
34ZVW2, 22.12.00
Department
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
35ZVW2, 22.12.00
1 2 3
4 5 6
7
*
8
0
9
#Clear Prog
Drill
Disable
Test
Teclas Numero usadas para entrar valores alfanumericos
Tecla Silence un espacio derecho Tecla Disable un espacio izquierda tecla #/Cmnd acepta datos cuando esta en modo programacion
Tecla */Clear usada para: Salir programacion alpha Exit entra modo program
History
Teclas de Programacion Alfanumerica
D7024 Programming
Reset
Silence
Programacion
Panel de Incendio D7024
#Cmnd
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
36ZVW2, 22.12.00
RAMIV - Adiciona la habilidad para programar remotamente, diagnosticar remotamente, recuperar historico remotamente
Programacion En sitio puede ser hecha usando un PC con RAMIV y un modem externo. Modem conexion Directa para deteccion tip/ring de lineas telefonicas entrantes en linea uno. Use RAMIV para conectar. Presione el boton Test en teclado D7024, presione 5 para Respuesta Remota, coloque nivel PIN maxima autoridad.
Programacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
37ZVW2, 22.12.00
Programacion Alpha Desde Teclado
Presione la tecla
Una = SPACE
Dos = 1
Tres veces = ,
Cuatro veces = ‘
Cinco veces = &
Seis veces = /
Siete veces= #
Ocho veces = !
Nueve veces = -
D7024 Programming
1
Programacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
38ZVW2, 22.12.00
Programacion Alpha Desde Teclado
1ra vez 2da vez 3ra vez 4ta vez
A B C 2
D E F 3
G H I 4
J K L 5
M N O 6
P R S 7
D7024 Programming
2
3
4
5
6
7
Programacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
39ZVW2, 22.12.00
Programacion Alpha Desde Teclado
1ra vez 2da vez 3ra vez 4ta vez
T U V 8
W X Y 9
Q Z 0
Entra descripcion & returna a menu programacion.
Returna a menu programacion sin hacer cambios.
Mueve cursor un espacio izquierda.
Mueve cursor un espacio derecha
D7024 Programming
8
9
0Prog
Cmd
*Clear
DisableSilence
#
Programacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
40ZVW2, 22.12.00
Nivel 1 es Menu Principal. Seleccione Programar con Tecla.
Nivel 2
1- PROG TIME
2- SECURITY
3- PROG SYSTEM
4- PROG INPUTS
5- PROG OUTPUTS
6- PROG ACC’NTS
7- PROG FORMATS
8- HISTORY DEFLTS
9- PROGRAM MUX
D7024 Program Menu Tree
0Prog
Arbol Programacion RAMIV, tiene igual info al display navegacion en teclado, excluyendo Nivel 2 item 8.
Programacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
41ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Program/ Hora
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
42ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Seguridad
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
43ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Program/ Sistema
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
44ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Program/ Entradas
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
45ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Programar Salidas
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
46ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Programar Cuentas
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
47ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Formatos Program/
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
48ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Historicos/Deflts
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
49ZVW2, 22.12.00
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
Arbol Menu Programacion
Program Mux
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
50ZVW2, 22.12.00
D7024s equipados con versiones software inferiores a
2.02 no pueden ser programados remotamente.
RAM IV Software Programacion Remota, Ver. 3.1.18 y
superior, es el programador remoto para el D7024
[Ver. 2.02 y superior].
D7024 Programming
Programacion RAM IV
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
51ZVW2, 22.12.00
Sistema permanece Operacional
Systema muestra
Sirenas no activan
Otras salidas programadas en Zona 62 se activaran
Problemas no se anuncian hasta sesion de programacion
finalice, pero apareceran en diagnosticos programador
Nuevas Alarmas terminan sesiones programacion &
reportan normalmente
D7024 Programming
SYSTEM TROUBLE RMT PRG ACTIVE
Programming Shortcuts
Programacion Remota
Programacion RAM IV
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
52ZVW2, 22.12.00
Para preparar el panel y poder programar con RAM IV usted
debe habilitar la opcion programacion remota: Presione 0 en el teclado
Pulse 9876 # Seleccione opcion 3 Programar Sistema Pulse 7 para Programacion Remota
Para Habilitar Presione 1 Presione la tecla * dos veces Presione 6 para Programar Cuentas Seleccione 4 para Conteo Rings
Colocar Auto Respuesta Conteo Rings 3
o 5
D7024 Programming
D7024 Guia Rapida Programacion
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
53ZVW2, 22.12.00
Para responder la llamada entrante desde RAM IV Presione la tecla Test despues 5 Preguntara para entrar un codigo. Teclee 9876 Pantalla mostrara “Remote Program Active”
D7024 Programming
D7024 Guia Rapida Programacion cont.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
54ZVW2, 22.12.00
Department
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
55ZVW2, 22.12.00
Modos de Operacion
D7024 Fire Alarm Control / Communicator
Existen tres modos de operar el sistema en el Control/Comunicador D7024 :
ALARM
TROUBLE
NORMAL
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
56ZVW2, 22.12.00
Modos de Operacion - Alarma
D7024 Fire Alarm Control / Communicator
ALARMA
Cuando una alarma ocurre, la linea superior de la pantalla mostrara “FIRE ALARM”, o un mensaje similar.
La segunda linea de la pantalla mostrara el numero de el punto que esta en alarma, alternando con la descripcion programada en el punto afectado.
Si mas de una alarma esta activa, se mostrara en la segunda linea de la pantalla, una despues de otra.
La sirena interna se activara con tono continuo, y las salidas programadas se activaran con la condicion de alarma actual que se active.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
57ZVW2, 22.12.00
Modos de Operacion - Trouble
D7024 Fire Alarm Control / Communicator
TROUBLE
Cuando una condicion de trouble sucede, la sirena se activara con un beep cada 10 segundos.
El LED de Trouble iluminara y el LCD mostrara “SYSTEM TROUBLE”, seguido por una descripcion de la condicion de trouble.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
58ZVW2, 22.12.00
Modos de Operacion – Señales Trouble
D7024 Fire Alarm Control / Communicator
TROUBLE
1. “FIRE ALARM”: Uno o mas puntos estan en alarma.
2. “SUP'VISORY ALARM”: Una condicion supervisada existe
3. “SYSTEM TROUBLE”: Una condicion trouble existe
4. “POINT TROUBLE”: Uno de los puntos no responde
5. “DISABLED DEVICE”: Un dispositivo de entrada o salida fue desabilitado.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
59ZVW2, 22.12.00
Modos de Operacion - Normal
D7024 Fire Alarm Control / Communicator
NORMAL
Cuando el sistema esta operando normalmente, este mostrara “SYSTEM NORMAL”.
En la linea superior de la pantalla, el LED de corriente estara encendido, y no otros LEDs alumbraran.
Si la programacion requiere un PIN, la segunda linea de la pantalla LCD mostrara “ENTER PIN:”
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
60ZVW2, 22.12.00
USO DEL SISTEMA – NAVEGANDO MENUS
D7024 Fuse re Alarm Control / CommunicatorPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
61ZVW2, 22.12.00
D7024 Fire Alarm Control / Communicator
Existen diferentes formas para seleccionar un item:
1. En el menu principal, TEST, HISTORY, DISABLE, y DRILL cada uno tiene un boton exclusivo en el teclado.
2. Las teclas PROG y CMND no son exclusivas, pero compartiran con otros caracteres. El caracter compartira la tecla correspondiente mostrada en la segunda linea seguida por un slash.
3. La tecla correspondiente al item sub-menu puede ser mostrada en la segunda linea precedido por un guion.
Panel de Incendio D7024
USO DEL SISTEMA – NAVEGANDO MENUS
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
62ZVW2, 22.12.00
OPERACION SISTEMA :
D7024 Fire Alarm Control / Communicator
•Una vez el Item Menu Principal Item fue seleccionadoCuando un item del Menu principal es seleccionado, el teclado podra preguntarle para entrar el PIN. •Devolviendose a travez del MenuPara returnar a la pantalla previa en cualquier momento, presione la tecla [*/Clear]. •Entrar DatosCuando un item del submenu se muestra para entrar el dato, hacerlo seguido por la tecla [#].•DrillEl comando drill activa todos los NACs y no los relays.•DesabilitarEl comando desabilitar se usa para desabilitar puntos entradas/salidas, o el discador•HistoriaLa opcion HISTORIA es una lista de eventos que han occurrido.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
63ZVW2, 22.12.00
HISTORIA ABREVIATURAS
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
64ZVW2, 22.12.00
TECLADO INCORPORADO
D7024 Fire Alarm Control / Communicator
LED Corriente LED Problema
LED Silenciar
Tecla Drill
Tecla Silenciar
Tecla Reset
Tecla Historia
Tecla ComandoTecla Programar
Tecla Limpiar
Tecla Prueba
Tecla Desabilitar
LED Alarma
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
65ZVW2, 22.12.00
TECLADO REMOTO
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
66ZVW2, 22.12.00
PRUEBA
D7024 Fire Alarm Control / Communicator
Test Caminado
Test Comunicador
Test Programacion Remota
Test Circuito Batteria/NAC
Test Activacion Salidas Manuales
Test Nivel Entradas Zona
Test Puntos Direccionables
•Para entrar en Modo Prueba presione la tecla Test
•Para salir del modo test presione la Tecla Clear
•Seleccione una de las siguientes funciones de prueba
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
67ZVW2, 22.12.00
Test Caminado
D7024 Fire Alarm Control / Communicator
Cuando seleccione esta opcion, tres opciones seran ofrecidas para la activacion de las salidas.
SHORT ACTIVE: 1 segundo activacion
LONG ACTIVE: 5 segundos activacion
NO ACTIVE: salidas no seran activadas
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
68ZVW2, 22.12.00
Test Comunicador
D7024 Fire Alarm Control / Communicator
El comunicador enviara un reporte de prueba.
El LED de corriente alumbrara durante la comunicacion.
Cuando la comunicacion se produce:un beep largo en el teclado se escuchara, el LED de Corriente retornara a normal, y la pantalla retornara a modo normal.
Terminando la funcion de prueba del comunicador se reseteara el comunicador y se descartaran los reportes no enviados.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
69ZVW2, 22.12.00
Test Programador Remoto
D7024 Fire Alarm Control / Communicator
El panel llamara al numero telefonico 3 e intentara conectarse para el downloading.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
70ZVW2, 22.12.00
Test Circuito Bateria/NAC
D7024 Fire Alarm Control / Communicator
En este modo de prueba, el sistema operara los circuitos locales NAC
y probara la bateria por dos segundos.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
71ZVW2, 22.12.00
Test Activacion Salidas Manuales
D7024 Fire Alarm Control / Communicator
Permite seleccionar una salida para ser activada y desactivada manualmente.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
72ZVW2, 22.12.00
Test Nivel Entradas Zona
D7024 Fire Alarm Control / Communicator
Muestra el estado de los puntos on-board seleccionados.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
73ZVW2, 22.12.00
Test Puntos Direccionables
D7024 Fire Alarm Control / Communicator
El test de puntos direccionables, o modo test mux, permite activacion de los modos especiales de prueba para
dispositivos direccionables, multiplex.
Cuando este modo de prueba es seleccionado, el sistema pregunta cual bus es probado. El sistema entonces presenta 5 opciones:
Lista DispositivosMuestra HoyosMuestra ExtrasMuestra PerdidosMuestra Estado
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
74ZVW2, 22.12.00
Ejemplo: X0L0R0D0M0T0F0A0
D7024 Fire Alarm Control / Communicator
X: reservado para uso futuro
L: estado relay comandado
R: estado relevo actual
D: detector sucio
M: dispositivo perdido
T: tamper
F: falla loop
A: loop de alarma
traduccion =
relay debe estar off
relay is off
no sucio
no perdido
no tamper
no falla
no alarma.
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
75ZVW2, 22.12.00
MAPEO PUNTO/ZONA
D7024 Fire Alarm Control / Communicator
El panel soporta un sist. Flex. para direccionar puntos entrada a puntos salida
Dispositivos seran designados como:
Puntos Entrada: Detectores Humo, estaciones manuales, etc.
Zona: Un grupo de puntos entrada (Zonas 1-50 son configurables, 52-63 son activadas automaticamente).
Puntos Salida : NACs (campanas, strobes, etc.) y relevos.
Activacion zonas entrada
Activacion salidas
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
76ZVW2, 22.12.00
Ejemplo Mapeo
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
77ZVW2, 22.12.00
Zonas Pre-asignadas
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
78ZVW2, 22.12.00
NUMEROS PIN
D7024 Fire Alarm Control / Communicator
El Numero de Identificacion Personal (PIN) es el codigo 4 digitos que el usuario entra en el teclado para ganar acceso al sistema
D7024 Panel – Usuarios 00 a 15
D7039 Modulo Expansion – Usuarios 16 a 99
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
79ZVW2, 22.12.00
OPERACION COMUNICADOR
D7024 Fire Alarm Control / Communicator
D7024 contiene un comunicador integrado que puede ser habilitado para enviar reportes a una estacion de monitoreo.
Alarmas de Fuego y flujo aguaseran enviadas primero, seguidas por:
alarmas supervision y reportes pruebay finalmente todos los demas reportes.
Lineas telefonicas para controles/comunicadores de fuego no deben ser compartidas
Panel de Incendio D7024
|
© Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as
copying and passing on to third parties.
80ZVW2, 22.12.00
Gracias
D7024 Fire Alarm Control / CommunicatorPanel de Incendio D7024