MURO 01DISEO DE MUROS DE CORTE

DATOS DE DISEO

Pu95.00 Tn2.80 mMu0.90 Tn-mVu2.00 TnLm3.90 m2.80 mfy4200 kg/cm2f`c210 kg/cm22.80 mMURO DE CORTE 01 B0.20 mL3.90 m2.80 m

3.90 m

3.90 m1. VERIFICACION DE ESBELTEZ

H15.10 mL3.90 mH/L3.87 mMURO ESBELTO

2. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

cDe compresion en fibra extremase debe cumplir que

c>0.20*f``c

c12.36 kg/cm2

0.20*f`c42.00 kg/cm2NO REQUIERE CONFINAMIENTO

3. VERIFICACION SI REQUIERE REFUERZOS A DOS CAPAS

SIVu >= 0.53*(f`c)^0.5*Acm

Vu2.00 TnFormula59.91 Tn NO SE REQUIERE

4. REFUERZOS MINIMOS

4.1 REFUERZO HORIZONTAL MINIMO AshminAcero a usarN 30.71 cm2Ashmin=hmin*Lm*emN 41.27 cm2N 51.98 cm2Ashmin=19.50 cm2S=28.40 cmh=0.0024USAR ESTRIBOS N 3 @ 0.30 m

4.2 REFUERZO VERTICAL MINIMO Asvmin

v=0.0025 + 0.5 (2.5 - Hm/Lm)*(h - 0.0025)

v=0.0026vmin=0.0026 USAR CUANTIAAshmin=5.18 cm2

USAR ESTRIBOS N 3 @ 0.27 m

5. VERIFICACION DE LA RESISTENCIA AL CORTE

Vn=2.35 TnVres=2.65*(f`c^0.5)*Acm

Vres=299.54 TnSI RESISTE

6. CONTRIBUCION DEL CONCRETO AL CORTE

Vc=*Acv*(f`c^0.5)

Hm/Lm=3.87 mUSAR 0.530.53

Vc= 59.91 Tn

Vs=-57.55 TnCORTANTE QUE SOPORTA EL ACERO

S=-32.33 cm

USAR 1 N 3 @0.12 mUSAR MINIMO26.58 cm

7. ELEMENTOS DE CONFINAMIENTO

APROXIMADAMENTEAh

bc=a/10.9d312 cm10.85

VERIFICACIONES a0.09 cmc0.11 cmNO SIRVEh>=C - 0.1*Lmh>=C/2h>=30 cmAPROXIMADAMENTEB

h=0.0024h>=-9.22 cmm=0.047h>=14.89 cm`=0.7h>=30 cm=0.058C=29.78 cm

ASUMIR C=30.00 cm

h=30.00 cmCONFINA. ASUMIDOb=30.00 cm

8. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

Pumax >=Pucolumna

PU columna47.50 TnAg900.00 cm2PU max133.47 TnCUMPLEAs18.00 cm219.32 cm2

USAR 4N 62.854N 51.98

MURO 02DISEO DE MUROS DE CORTE

DATOS DE DISEO

Pu217.00 Tn2.80 mMu1.20 Tn-mVu2.00 TnLm3.00 m2.80 mfy4200 kg/cm2f`c210 kg/cm22.80 mMURO DE CORTE 01 B0.20 mL3.00 m2.80 m

3.90 m

3.00 m1. VERIFICACION DE ESBELTEZ

H15.10 mL3.00 mH/L5.03 mMURO ESBELTO

2. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

cDe compresion en fibra extremase debe cumplir que

c>0.20*f``c

c36.57 kg/cm2

0.20*f`c42.00 kg/cm2NO REQUIERE CONFINAMIENTO

3. VERIFICACION SI REQUIERE REFUERZOS A DOS CAPAS

SIVu >= 0.53*(f`c)^0.5*Acm

Vu2.00 TnFormula46.08 Tn NO SE REQUIERE

4. REFUERZOS MINIMOS

4.1 REFUERZO HORIZONTAL MINIMO AshminAcero a usarN 30.71 cm2Ashmin=hmin*Lm*emN 41.27 cm2N 51.98 cm2Ashmin=15.00 cm2S=28.40 cmh=0.0024USAR ESTRIBOS N 3 @ 0.30 m

4.2 REFUERZO VERTICAL MINIMO Asvmin

v=0.0025 + 0.5 (2.5 - Hm/Lm)*(h - 0.0025)

v=0.0027vmin=0.0027 USAR CUANTIAAshmin=5.34 cm2

USAR ESTRIBOS N 3 @ 0.27 m

5. VERIFICACION DE LA RESISTENCIA AL CORTE

Vn=2.35 TnVres=2.65*(f`c^0.5)*Acm

Vres=230.41 TnSI RESISTE

6. CONTRIBUCION DEL CONCRETO AL CORTE

Vc=*Acv*(f`c^0.5)

Hm/Lm=5.03 mUSAR 0.530.53

Vc= 46.08 Tn

Vs=-43.73 TnCORTANTE QUE SOPORTA EL ACERO

S=-32.73 cm

USAR 1 N 3 @0.12 mUSAR MINIMO20.45 cm

7. ELEMENTOS DE CONFINAMIENTO

APROXIMADAMENTEAh

bc=a/10.9d240 cm10.85

VERIFICACIONES a0.16 cmc0.18 cmNO SIRVEh>=C - 0.1*Lmh>=C/2h>=30 cmAPROXIMADAMENTEB

h=0.0024h>=17.75 cmm=0.047h>=23.88 cm`=0.7h>=30 cm=0.172C=47.75 cm

ASUMIR C=47.75 cm

h=30.00 cmCONFINA. ASUMIDOb=30.00 cm

8. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

Pumax >=Pucolumna

PU columna108.50 TnAg900.00 cm2PU max133.47 TnCUMPLEAs18.00 cm219.32 cm2

USAR 4N 62.854N 51.98

MURO 03DISEO DE MUROS DE CORTE

DATOS DE DISEO

Pu168.00 Tn2.80 mMu1.20 Tn-mVu2.50 TnLm2.70 m2.80 mfy4200 kg/cm2f`c210 kg/cm22.80 mMURO DE CORTE 01 B0.20 mL2.60 m2.80 m

3.90 m

2.60 m1. VERIFICACION DE ESBELTEZ

H15.10 mL2.60 mH/L5.81 mMURO ESBELTO

2. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

cDe compresion en fibra extremase debe cumplir que

c>0.20*f``c

c31.64 kg/cm2

0.20*f`c42.00 kg/cm2NO REQUIERE CONFINAMIENTO

3. VERIFICACION SI REQUIERE REFUERZOS A DOS CAPAS

SIVu >= 0.53*(f`c)^0.5*Acm

Vu2.50 TnFormula39.94 Tn NO SE REQUIERE

4. REFUERZOS MINIMOS

4.1 REFUERZO HORIZONTAL MINIMO AshminAcero a usarN 30.71 cm2Ashmin=hmin*Lm*emN 41.27 cm2N 51.98 cm2Ashmin=13.00 cm2S=28.40 cmh=0.0025USAR ESTRIBOS N 3 @ 0.28 m

4.2 REFUERZO VERTICAL MINIMO Asvmin

v=0.0025 + 0.5 (2.5 - Hm/Lm)*(h - 0.0025)

v=0.0024vmin=0.0025USAR CUANTIA 0.0025Ashmin=5.00 cm2

USAR ESTRIBOS N 3 @ 0.28 m

5. VERIFICACION DE LA RESISTENCIA AL CORTE

Vn=2.94 TnVres=2.65*(f`c^0.5)*Acm

Vres=199.69 TnSI RESISTE

6. CONTRIBUCION DEL CONCRETO AL CORTE

Vc=*Acv*(f`c^0.5)

Hm/Lm=5.81 mUSAR 0.530.53

Vc= 39.94 Tn

Vs=-37.00 TnCORTANTE QUE SOPORTA EL ACERO

S=-33.53 cm

USAR 1 N 3 @0.12 mUSAR MINIMO17.72 cm

7. ELEMENTOS DE CONFINAMIENTO

APROXIMADAMENTEAh

bc=a/10.9d208 cm10.85

VERIFICACIONES a0.18 cmc0.21 cmNO SIRVEh>=C - 0.1*Lmh>=C/2h>=30 cmAPROXIMADAMENTEB

h=0.0025h>=12.18 cmm=0.051h>=19.09 cm`=0.7h>=30 cm=0.154C=38.18 cm

ASUMIR C=30.00 cm

h=30.00 cmCONFINA. ASUMIDOb=30.00 cm

8. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

Pumax >=Pucolumna

PU columna84.01 TnAg900.00 cm2PU max133.47 TnCUMPLEAs18.00 cm219.32 cm2

USAR 4N 62.854N 51.98

MURO 04DISEO DE MUROS DE CORTE

DATOS DE DISEO

Pu173.00 Tn2.80 mMu1.25 Tn-mVu2.60 TnLm2.60 m2.80 mfy4200 kg/cm2f`c210 kg/cm22.80 mMURO DE CORTE 01 B0.20 mL2.60 m2.80 m

3.90 m

2.60 m1. VERIFICACION DE ESBELTEZ

H15.10 mL2.60 mH/L5.81 mMURO ESBELTO

2. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

cDe compresion en fibra extremase debe cumplir que

c>0.20*f``c

c33.82 kg/cm2

0.20*f`c42.00 kg/cm2NO REQUIERE CONFINAMIENTO

3. VERIFICACION SI REQUIERE REFUERZOS A DOS CAPAS

SIVu >= 0.53*(f`c)^0.5*Acm

Vu2.60 TnFormula39.94 Tn NO SE REQUIERE

4. REFUERZOS MINIMOS

4.1 REFUERZO HORIZONTAL MINIMO AshminAcero a usarN 30.71 cm2Ashmin=hmin*Lm*emN 41.27 cm2N 51.98 cm2Ashmin=13.00 cm2S=28.40 cmh=0.0024USAR ESTRIBOS N 3 @ 0.30 m

4.2 REFUERZO VERTICAL MINIMO Asvmin

v=0.0025 + 0.5 (2.5 - Hm/Lm)*(h - 0.0025)

v=0.0027vmin=0.0027 USAR CUANTIAAshmin=5.44 cm2

USAR ESTRIBOS N 3 @ 0.26 m

5. VERIFICACION DE LA RESISTENCIA AL CORTE

Vn=3.06 TnVres=2.65*(f`c^0.5)*Acm

Vres=199.69 TnSI RESISTE

6. CONTRIBUCION DEL CONCRETO AL CORTE

Vc=*Acv*(f`c^0.5)

Hm/Lm=5.81 mUSAR 0.530.53

Vc= 39.94 Tn

Vs=-36.88 TnCORTANTE QUE SOPORTA EL ACERO

S=-33.64 cm

USAR 1 N 3 @0.12 m

7. ELEMENTOS DE CONFINAMIENTO

APROXIMADAMENTEAh

bc=a/10.9d208 cm10.85

VERIFICACIONES a0.19 cmc0.22 cmNO SIRVEh>=C - 0.1*Lmh>=C/2h>=30 cmAPROXIMADAMENTEB

h=0.0024h>=12.78 cmm=0.047h>=19.39 cm`=0.7h>=30 cm=0.158C=38.78 cm

ASUMIR C=30.00 cm

h=30.00 cmCONFINA. ASUMIDOb=30.00 cm

8. VERIFICACION DE ELEMENTOS DE CONFINAMIENTO

Pumax >=Pucolumna

PU columna86.51 TnAg900.00 cm2PU max133.47 TnCUMPLEAs18.00 cm219.32 cm2

USAR 4N 62.854N 51.98