IO-Link : standard communication (IEC 61131-9) for sensors and actuators
http://www.io-link.com/share/Downloads/At-a-glance/IO-Link_System_Description_engl_2013.pdf
• IO-Link is a serial, bidirectional point-to-point connection for signal transmission and energy supply under any networks, fieldbuses, or backplane buses. IO-Link is not a field bus.
• Powerful point-to-point communication based on established 3/5 wire sensor and actuator/drive connection without additional requirements regarding the cable material.
IO Link enables data communication from the field device to ERP system
Festo IO–Link advantages:• Cost effective, field device connection:• Pre-engineered mechatronics systems – OMS (Optimized Motion Series)• Scalable system: flexibility on device management• 3-5 wire cable, unshielded, M12 connector for fast and reliable connection
point• Bidirectional data transmission• IoT (Internet of Things), Industry 4.0 ready• ADP (Automatic Device Configuration): parameter storage in upper controller• Field device replacement with no commissioning: “plug and play”.• Data reporting (remote diagnose, alarms, trips) allows for easy
troubleshooting• Standardized field device connection technology• Adopted by all major Automation suppliers• Master IO Link Compatible with all major Bus communication
Important IO-Link Basics: NOT a fieldbus Requires an IO-Link
Master M12 ports typical Uses standard cables
I-Port
I-Port
Industrial Ethernet
- “the smart automation solution for the last meter of installation”
IO Link application advantage example on Rockwell environment:
• 25 conductors
• no diagnostics
• 5 conductors
• diagnostics
Customers who only specify Rockwell I/O will typically use MP valve terminals:• High termination costs• High cable costs• No diagnostics
Same customers can use IO-Link valve terminals:• Low termination costs• Low cable costs• Diagnostics• Automatic
configuration
Rockwell Point I/O - 1734-4IOL IO-link Master
Festo IO-Link Master: CECC-LK Mechatronic Controller
Pick & Place Handling System (max. 8 drives / PtP Only)
VTUB CTSL
VTUG MPA-L
Modbus TCP
Festo IO-Link Products
CMMO
Stepper motor actuator
4 IO-Link ports
CECC-LK
CPX I-Port Master for IO-Link devices vs. CTEL-MasterSolution for simple RIO modules
CPX with I-Port MasterSolution for smart sensors & actuators
CPX with I-Port Master for IO-Link devices
Festo I-Port for valve terminals & input modulesStandard IO-Link devices (V1.0 & V1.1)
4 Ports 2 Ports
Festo Master for IO-Link devices – CPX-CTEL …-LK -
http://ademtp00.de.festo.net/SpimsPlus/DocumentDetails_ps.aspx?DOCID=10000565642&LNG=en-IV
• Amount of ports for IO-Link devices: 2 (X1 & X2)
• Port type B, US1/US2 isolated
• Only available with EtherNet/IP (CPX-FB36R12), PROFINET & Sercos
Compatible to Siemens function block IOL-CALL
• Product description: CPX-CTEL-2-M12-5POL-LK
• Part number: TN2900543
• No compliance with standards to IO-Link masters Therefore it is called I-Port-Master for IO-Link devices
IO-Link over CTEU to CTEL installation system
CTEU/CAPCFlexible installationof fieldbus and I/O
CTEUDirect integration of fieldbus
CPX/CTELIntegration into a completesystem with CPX and control
The Festo I-Port interface is supported by different network or automation systems as for example the CPX-CTEL installation system. The valve terminal is always the same.
IO-Link Mode
Festo IO-Link devices – valve terminals
CPV-10/14
VTUG-… + VAEM-…-PT
MPA-C
MPA-L
VTOC-… + Interlock
VTUG-… + Interlock
Festo IO-Link devices – Sensors
SPAUPressure Sensor
SPAEPressure Sensor
SDATCylinder Position Transducer
Festo IO-Link devices: Proportional Pressure Regulators and Vacuum Generator
VPPM is the first proportional valve with IO-Link connectiontechnology.
Vacuum Generator OVEM-..-LK
Integrating Festo IO-Link devices into Rockwell Automation network
Main Points:Premier Integration with
Encompass Referenced Products from Festo
• Similar integration as Rockwell IO-link
CMMO-LK + Actuator• Cost Effective• No similar offering from RA• FHPP• FHPP + FPC• IO-Link VAEM for IO-Link (Referenced)MPA-L for IO-Link (Referenced)