6
FORMULAS UTILIZADAS PARA LAS TUBERIAS CERRADAS: a ij = L ij ( 0.279 C n ij D ij 2.63 ) 1.85 D ij = √ 4 a ij πv ∆Q= − ∑ a ij Q ij n n ( ∑ a ij Q ij n−1 ) h ij =a ij Q ij n CIRCUITO I TRAMO 2-3: 1. CALCULO DE DIAMETRO D 23 = √ 4 Q 23 πv D 23 = √ 4∗0.1 π∗2.3 D 23 =0.2353 ≈ 0.24 2. CALCULO DE “ a ij ” a 23 = L 23 ( 0.279 C n 23 D 23 2.63 ) 1.85 a 23 = 700 ( 0.279∗1.85∗0.24 2.63 ) 1.85 a 23 =824.0918164 ≈ 824.09 3. CALCULO DE “ Q ij n ” Q 23 n =0.1 1.85
-
Upload
anthony-bazan-rodriguez -
Category
Documents
-
view
2 -
download
1
description
Formulas Utilizadas Para Las Tuberias
Transcript of Formulas Utilizadas Para Las Tuberias Cerradas
FORMULAS UTILIZADAS PARA LAS TUBERIAS CERRADAS:
CIRCUITO ITRAMO 2-3:1. CALCULO DE DIAMETRO
2. CALCULO DE
3. CALCULO DE
4. CALCULO DE
5. CALCULO DE
6. CALCULO DE
TRAMO 3-4:1. CALCULO DE DIAMETRO
2. CALCULO DE
3. CALCULO DE
4. CALCULO DE
5. CALCULO DE
6. CALCULO DE
TRAMO 4-5:1. CALCULO DE DIAMETRO
2. CALCULO DE
3. CALCULO DE
4. CALCULO DE
5. CALCULO DE
6. CALCULO DE
TRAMO 5-2:1. CALCULO DE DIAMETRO
2. CALCULO DE
3. CALCULO DE
4. CALCULO DE
5. CALCULO DE
6. CALCULO DE
TOTALES
CALCULO DE DIFERENCIAL DE CAUDAL
NOTA: SIGUIENDO PROCEDIMIENTO HALLAMOS LOS DEMAS CIRCUTOS CERRADOS