    Maintenance Management And Rehabilitation

    ofReinforced Concrete Structures

    Technical Presentation

    to ORC

    By

    Tony Carpenter, B.Eng, C.Eng, MIStructE.

    Regional Manager

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    2/39

    All Elements and Materials Deteriorate

    For structures it is important to define at the outset

    the required useful life expectancy.

    We term life expectancy

    Service Life

    Introduction

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    3/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    4/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    5/39

    Physical Deterioration

    Fire Damage

    Over Loading by tenants/occupier

    Thermal Expansion and Contraction

    Impact Damage and Abuse

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    6/39

    Chemical Deterioration

    Sulphate Attack

    Alkali-Aggregate Reactions

    Chemical Spillage

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    7/39

    Electro-Chemical Deterioration

    Corrosion or rusting of steel reinforcement,

    having been depassivated either by

    Carbonation or Chloride contamination ofsurrounding concrete, or a combination of

    the two.

    Chloride Induced Electro-chemical

    deterioration is generally the most common

    form of reinforced concrete deterioration

    experienced in the Gulf.

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    8/39

    Electro-Chemical Deterioration

    Internal Cracking and Spalling

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    9/39

    Electro-Chemical Deterioration

    External Cracking and Spalling

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    10/39

    Electro-Chemical Deterioration

    Deterioration of Bridge Structure

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    11/39

    Attack of gasses Attack of non-electrolytes

    e.g. oils

    Chemical corrosion

    Atmospherically

    exposed steel

    structures

    (air and water)

    Anodic and Cathodic

    areas wich cannot

    be separated

    Micro-electrolytic

    corrosion

    Submerged og

    cast in items

    in water, soil or

    concrete

    Separate

    Anodic and Cathodic

    areas

    Macro-electrolytic

    corrosion

    Electrochemical corrosion

    Corrosion

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    12/39

    Micro-electrolytic Corrosion

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    13/39

    Macro-electrolytic Corrosion

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    14/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    15/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    16/39

    CO2

    Cl-

    Cl-

    Cl-

    Cl-

    Cl-

    Cl-

    Cl-CO2CO2

    CO2CO2

    CO2CO2

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    17/39

    CO2

    Cl-

    Cl-Cl-

    Cl-

    Cl-

    Cl-

    Cl-CO2CO2

    CO2CO2

    CO2CO2

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    18/39

    CO2

    Cl-

    Cl-

    Cl-

    Cl-

    Cl-

    Cl-

    Cl-CO2CO2

    CO2CO2

    CO2CO2

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    19/39

    Fe++

    2e-

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    20/39

    2Fe 2Fe++ + 4e-

    Anode Cathode

    4e- + O2 + 2H2O 4(OH)-

    2Fe + O2 + 2H2O 2Fe++ + 4(OH)-

    O2

    O2

    O2

    H2O H2O

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    21/39

    0 1 2 3 4 5 6 7

    Fe

    FeO

    Fe3O4

    Fe2O3

    Fe(OH)2

    Fe(OH)3

    Fe(OH)3, 3H2O

    Volume

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    22/39

    Transport Mechanisms

    Concrete contaminated during construction

    Capillary Action

    Permeation

    Diffusion

    Osmosis (coatings)

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    23/39

    Transport Mechanisms

    MOISTURE ONLY

    EVAPORATION OF

    DIFFUSION

    GF SLAB

    CAPILLARYGW L

    MOVEMENT

    MOISTURE

    DIFFUSION

    COLUMN

    DIFFUSION

    EVAPORATION OF

    MOISTURE ONLY

    FOOTING

    BLINDING

    CONCRETE

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    24/39

    Transport Mechanisms

    S E E P A G E

    D I F F U S I O N

    G W L

    G L

    B L I N D I N G

    C O N C R E T E

    E V A P O R A T I O N O F

    M O I S T U R E O N L Y

    M O I S T U R E O N L Y

    E V A P O R A T IO N O F

    C A P I L L A R Y /

    M O V E M E N T

    M O I S T U R E

    B A S E M E N T W A L L

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    25/39

    Service Life

    Technical Service life

    Age of Structure

    Acceptable Limit

    Initiation Phase Propagation Phase

    Damage

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    26/39

    Achieving Service Life

    Design

    Materials

    Workmanship

    Preventive Maintenance

    Repairs/Rehabilitation

    Substantial Reconstruction

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    27/39

    Technical Service life

    Age of Structure

    Acceptable Limit

    Damage

    The Law of Fives (de Sitter)

    A B C D

    Service Life Curve

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    28/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    29/39

    Existing Structures

    Existing structures are principally

    within:

    Phase B

    Phase C

    Phase D

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    30/39

    Existing Structures

    Age of many concrete structure means

    owners becoming faced with rapidly

    increasing maintenance/rehabilitation

    costs as deterioration move to phase D.

    Why?

    Lack of trained civil maintenance staff

    Low priority given to civil works

    No real appreciation of condition and

    consequences of not taking action

    No medium term planning

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    31/39

    Actions to be Taken

    Adopt same attitude to civil works as

    applied to plant!

    Develop maintenance programme for

    reinforced concrete structures

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    32/39

    Advantages/Benefits

    Budgets planned well in advance

    Human resources efficiently managed

    Operations planned to minimise disruption of users

    Extends service life of structure

    Maintains capital investment

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    33/39

    Maintenance Management

    Start with Investigation of Structures

    Archive search

    Site investigation

    - Visual inspection

    - Sampling and testing

    Assessment and RecommendationsPrioritise rehabilitation activities

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    34/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    35/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    36/39

    Time For Intervention

    CRITICALITY CODE DAMAGE CODE DETERMINING FACTOR

    1 2 3 4

    1 A B C* D* Life/Welfare, Capital loss

    2 A/B B/C C* D* Interruption of operation

    3 B/C C* D* D* Maintenance inconvenience

    4 E* E* E* E* Cost effectiveness

    A Immediate Action D < 6 years

    B < 1 year E at failure

    C < 3 years

    * Based on regular inspection and monitoring

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    37/39

    Recommendations

    Strategies and Concepts For

    Remedial Works

    Other Important Factors

    Operational Constraints

    - Special Temporary supports required

    for structure

    - Plant and equipment cannot be

    relocated, diverted or decommissioned

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    38/39

  • 7/29/2019 ORC Gereal Presentation - Conc Main.ppt

    39/39

    Thank You for YourAttention