Prac 6. Bombas en Serie
-
Upload
conchita-paredes -
Category
Documents
-
view
218 -
download
3
description
Transcript of Prac 6. Bombas en Serie
Paredes Guauxochitl Mara Concepcin
Prctica #6: Bombas en serie
Problema: Los datos elctricos de las placas de los motores de las tres bombas instaladas en el mdulo de bombeo (Fig.1) son 0.75, 1.0 y 1.5 Hp. Estas se pueden interconectar entre si, para operar a dos de ellas en serie, encuentre las alternativas posibles y seleccione la que opere con mayor eficiencia, cuando en el sistema hidrulico se requiere un flujo de 35 L/min. Y una cabeza total de 41 m.
Datos:Bomba 3APDPDPsP(PLACA)QPot ElectricaI
Datoskg/cmkg/mkg/mkg/mL/minWAmpere
11.5715700-815.70.85198.907725667008.2
21.7517500-543.80.685.888820226607.9
31.851850000.2664.410525515887.44
42200002000.00442.043457734717.05
52.1221200400041.6070174406.66
Bomba 2BPDPDPsP(PLACA)QPot ElectricaI
Datoskg/cmkg/mkg/mkg/mL/minWAmpere
11.515000-2039.250.953103.749717008.9
21.616000-1359.50.83698.17631826508.97
31.818000-679.750.57384.374204386408.4
422000000.20660.342831775587.98
52.1210000041.6070174207.34
Bomba 1CPDPDPsP(PLACA)QPot ElectricaI
Datoskg/cmkg/mkg/mkg/mL/minWAmpere
11.616000-1359.51.45124.763348894211.9
21.7517500-1223.551.216115.331471194412.4
31.919000-679.750.926102.489436193212.2
4220000-135.950.74893.7752524988711.4
52.424000100041.60701754210.4
Bomba 2B+1CPDPDPSP(PLACA)QPot ElectricaI
Datoskg/cmkg/mkg/mkg/mL/minWAmpere
12.222000-27191.948142.8332387190021.6
22.323000-2447.11.855139.6314729189021.5
32.626000-2173.61.635131.7571361181021.1
42.828000-2037.751.45124.7633488175020.6
54.45445000041.60701798817.2
Bomba 3A+2BPDPDPSP(PLACA)QPot ElectricaI
Datoskg/cmkg/mkg/mkg/mL/minWAmpere
12.323000-1631.41.418123.514705155017.5
22.525000-1495.451.312119.2882801155017.3
32.727000-1359.51.117111.1086443149016.8
4330000-815.70.85599.10189135143016.5
54.141000200041.60701785413.7
Bomba 3A+1CPDPDPSP(PLACA)QPot ElectricaI
Datoskg/cmkg/mkg/mkg/mL/minWAmpere
12.121000-2447.11.854139.5966573193021.3
22.222000-2311.151.752136187021.1
32.424000-2135.21.147112.4044673182020.7
42.626000-1767.351.16112.9615321177020.4
54.444000400041.60701795016.5
Memoria de clculo:
Resultados:Bomba 3AWf (PD-Ps)/WfQEficiencia
DatosmJ/KgKg/s%
116.5157161.96368941.6484620938.1415718
218.0438176.94923131.4314803438.3786887
318.5181.4230251.0735087633.122314
419.8194.171670.700724328.8876447
520.8203.978320.6934502832.14746
Bomba 2BWf (PD-Ps)/WfQEficiencia
DatosmJ/KgKg/s%
117.03925167.0979611.7291618341.2770595
217.3595170.23854071.6362719742.8548542
318.67975183.18577031.4062367440.2504001
420196.1331.0057138635.3501213
521205.939650.6934502834.0021211
Bomba 1CWf (PD-Ps)/WfQEficiencia
DatosmJ/KgKg/s%
117.3595170.23854072.0793891537.578787
218.72355183.61530161.9221911937.3881053
319.67975192.99242031.7081572735.3713954
420.13595197.46621411.5629208734.7941452
523.9234.3789350.6934502829.9871105
Bomba 2B+1CWf (PD-PS)/WfQEficiencia
DatosMJ/KgKg/s%
124.719242.41058142.3805539830.3721828
225.4471249.55080322.3271912130.7276422
328.1736276.28863442.1959522733.5202571
430.03775294.5697012.0793891535.0014308
544.5436.3959250.6934502830.6294411
Bomba 3A+2BWf (PD-PS)/WfQEficiencia
DatosmJ/KgKg/s%
124.6314241.55151882.0585784232.0808221
226.49545259.83160471.98813833.3278121
328.3595278.11169071.8518107434.564444
430.8157302.19878441.6516981934.904978
540.8400.111320.6934502832.4891462
Bomba 3A+1CWf (PD-PS)/WfQEficiencia
DatosmJ/KgKg/s%
123.4471229.93750322.3266109627.7189178
224.31115238.41093912.2666666728.8982957
326.1352256.29875911.8734077926.381983
427.76735272.30468291.882692228.9641753
543.6427.569940.6934502831.210368
Cuestionario:1. Con la informacin contenida en las tablas de datos experimentales, hacer los clculos necesarios para obtener en cada arreglo:a) La cabeza en (m.) b) La capacidad (flujo volumtrico) en (L/min.) c) La potencia elctrica en (W) d) La potencia hidrulica en (Kgf. m. / Kg.) y e) % de eficiencia Tabla de resultados.
2. Con los resultados anteriores, construir para cada arreglo las siguientes graficasa) Capacidad (flujo volumtrico) (L/min) VS Columna Total (m) b) Capacidad (flujo volumtrico) VS Potencia Hidrulica (Kfm/min.) c) Capacidad (flujo volumtrico) VS Eficiencia.a)
b)
3. Analizar las grficas resultante del punto15-2, Para resolver el problema planteado Para obtener una cabeza total de 41m se tuvo que hacer un arreglo de bombas en serie utilizando las bombas 2B y 1C.
4. Indicando:a) Las bombas que integran el arreglo que da solucin al problema planteado.El arreglo es el de 2B+1C.b) Los Watts que consume y la eficiencia con que opera el arreglo.El arreglo consume 1667.6 Watts y la eficiencia promedio es de 32.05%
Conclusiones:Se pudo resolver el problema utilizando un arreglo de bombas en serie con las bombas 2B+1C, esto se pudo hacer ya que se sabe que al arreglar las bombas en serie se suman las cabezas de cada bomba, en este caso se alcanz el objetivo porque se usaron las bombas con mayor potencia.