Predimensionado de columnas

9
PREDIMENSIONADO DE COLUMNAS ELABORADO POR: BARBERI, ISABELLA BAZAN, EDSON CALO, PEDRO SALAZAR, YULAIS Sección 4A CONSTRUCCION II PORLAMAR, OCTUBRE 2015

Transcript of Predimensionado de columnas

Page 1: Predimensionado de columnas

PREDIMENSIONADO DE COLUMNAS

ELABORADO POR:BARBERI, ISABELLA

BAZAN, EDSONCALO, PEDRO

SALAZAR, YULAIS

Sección 4A

CONSTRUCCION II

PORLAMAR, OCTUBRE 2015

Page 2: Predimensionado de columnas

IDENTIFICACION DE LOS TIPOS DE COLUMNASLEYENDA

COLUMNAS EQUINERAS

COLUMNAS CENTRALES

COLUMNAS LATERALES

3.65

1.33

1.203

.35

3.35

3.65

Page 3: Predimensionado de columnas

IDENTIFICACION DE LOS TIPOS DE COLUMNASLEYENDA

COLUMNAS ESQUINERAS

COLUMNAS CENTRALES

COLUMNAS LATERALES

3.653.65

2.624.13

1.20

Page 4: Predimensionado de columnas

Planta BajaÁrea Tributaria:

* A1: 1.67x3.17: 5.29 kg/m2* A2: 3.35x3.17: 10.61 kg/m2*A3: 1.67x3.17: 5.29 kg/m2

*B1: 1.67x3.65: 6.09 kg/m2*B2: 3.35x3.65: 12.22 kg/m2*B3: 1.67x3.65: 6.09 kg/m2

*C1: 1.67x3.02: 5.04 kg/m2*C2: 3.35x3.02: 10.11 kg/m2*C3: 1.67x3.02: 5.04 kg/m2

Page 5: Predimensionado de columnas

Planta BajaCarga Axial:

*A1: P:1000x5.29x2: 10580 kg*A2: P:1000x10.61x2: 21220 kg*A3: P:1000x5.29x2: 10580 kg

*B1: P:1000x6.09x2: 12180 kg*B2: P:1000x12.22x2: 24440 kg*B3: P:1000x6.09x2: 12180 kg

*C1: P:1000x5.04x1: 5040 kg*C2: P:1000x10.11x1: 10110 kg*C3: P:1000x5.04x1: 5040 kg

Page 6: Predimensionado de columnas

Planta Baja Área Tributaria:

A1: Ac: 10580: 302 cm2 0.20x175 19.5x15.5A2: Ac: 21220 : 485 cm2 0.25x175 31.3x15.5A3: Ac: 10580 : 302 cm2 0.20x175 19.5x15.5

B1: Ac: 12180 : 278 cm2 0.25x175 18.15.5B2: Ac: 24440 : 499 cm2 0.28x175 18x15.5B3: Ac: 12180 : 278 cm2 0.25x175 18x15.5C1: Ac: 5040 : 144 cm2 0.25x175 9.3x15.5C2: Ac: 10110 2.37 cm2 0.25x175 14.9x15.5C3: Ac: 5040 144 cm2 0.20x175 9.3x15.5

Page 7: Predimensionado de columnas

Planta AltaArea Tributaria:

*A1: 1.67x3.19: 5.32 kg/m2*A2: 3.35x3.19: 10.68 kg/m2*A3: 1.67x3.19: 5.32 kg/m2

*B1: 1.68x1.82: 3.03 kg/m2*B2: 3.35x3.82: 6.09 kg/m2*B3: 1.67x1.82: 3.01 kg/m2

Page 8: Predimensionado de columnas

Planta AltaCarga Axial:

*A1: P:1000x5.3:29x1: 5320*A2: P:1000x10.68x1: 10680*A3: P:1000x5.32x1: 5320

*B1: P:1000x3.03x1: 3030*B2: P:1000x6.09x1: 6090*B3: P:1000x3.03x1: 3030

Page 9: Predimensionado de columnas

Planta Alta*A1: Ac: 5320 :152

0.20x150 9.8x15.5*A2: Ac: 10680: 244 0.25x175 9.8x15.5*A3: Ac: 5320 : 152 0.20x175 9.8x15.5

*B1: Ac: 3030 : 69 0.25x175 4.45x15.5*B2: Ac: 6090 : 124 0.28x175 9x15.5*B3: Ac: 3030: 69 0.25x175 4.45x15.5