![Page 1: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/1.jpg)
M 40 DEL AGUA
EMPLEO DE AGUA REGENERADA EN
EL AYUNTAMIENTO DE MADRID
Pedro M. Catalinas Montero
Zaragoza, 14 de enero de 2015
![Page 2: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/2.jpg)
14 de Julio 2005 31 de mayo 2006
![Page 3: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/3.jpg)
METAS DEL PLAN DE GESTIÓN
Asegurar la calidad y la cantidad del agua que se suministra a los ciudadanos de Madrid.
Alcanzar una reducción del 12% del consumo de agua potable para el año 2011.
Fomentar el uso de nuevas tecnologías para
incrementar el uso eficiente del agua, su ahorro y
promover su reutilización y reciclado . Minimizar la carga contaminante de los efluentes
vertidos, evitando el deterioro de los recursos hídricos.
![Page 4: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/4.jpg)
BENEFICIOS DE LA REUTILIZACIÓN DIRECTA Y PLANIFICADA DE AGUAS REGENERADAS
Incremento de los recursos hídricos disponibles. Colaborar en el desarrollo sostenible del recurso. Ahorro del consumo de agua potable. Garantizar el suministro de agua. Disminución del caudal de agua residual tratada vertida a los
cauces naturales. Reducción del aporte de contaminantes a los cursos
naturales de agua. Reducción de los costes de captación, transporte y
tratamiento de agua potable para abastecimiento. Disminución del coste de mantenimiento de zonas verdes por
el aprovechamiento de los elementos nutritivos contenidos en el agua.
![Page 5: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/5.jpg)
ESQUEMA DE ACTUACIÓN ANTE UN PROYECTO DE REUTILIZACIÓN DE AGUAS REGENERADAS
Proyecto de reutilización de agua – Definir los niveles de calidad adecuados para cada
uno de los posibles usos.– Establecer los procesos de tratamiento y los límites de
calidad del efluente.
Requerimientos del aprovechamiento – Construcción de la planta regeneradora.– Ejecución de las redes de transporte desde la planta
de regeneración hasta su lugar de utilización.– Instalación de los sistemas de almacenamiento o
regulación para adecuar el caudal suministrado por la planta con los caudales consumidos por los usuarios.
– Definición de unas normas de utilización del recurso.
![Page 6: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/6.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED CENTRO – CRITERIOS DE DISEÑO
• Calidad del agua reutilizada– pH 6-9– Sólidos en Suspensión < 10 mg/l– DBO5 < 10 mg/l– Coliformes Fecales < 10 ufc /100 ml.– Huevos de Nemátodos < 1 huevo/l
• Red de distribución– Depósito primario– Depósitos secundarios– Red a demanda
![Page 7: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/7.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED CENTRO – PLANTA TRATAMIENTO
Capacidad Diaria: 37.600 m3/día
![Page 8: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/8.jpg)
PLAN DE REUTILIZACIÓN DE AGUARED CENTRO
![Page 9: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/9.jpg)
PLAN DE REUTILIZACIÓN DE AGUASIDENTIFICACIÓN DE ZONAS REGADAS
![Page 10: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/10.jpg)
PLAN DE REUTILIZACIÓN DE AGUASESPECIFICACIONES DE LAS INSTALACIONES
Independencia entre las redes de agua potable y agua reutilizada
Las conducciones de agua potable deberán estar lo suficientemente separadas.
Las tuberías y accesorios serán de color violeta (PANTONE 2577U ó RAL 4001) al igual que los aspersores.
Todas las válvulas, grifos y cabezales de aspersión deberán además, estar marcados adecuadamente.
Las tuberías y las tapas de las arquetas tendrán una leyenda fácilmente legible “AGUA REGENERADA. AGUA NO POTABLE”.
Se deberán utilizar aspersores de tipo emergente.
Las fuentes de agua potable deberán estar protegidas de las aerosoles de agua reutilizada.
Cualquier zona frecuentada por el público deberá disponer de un número adecuado de fuentes de agua potable.
![Page 11: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/11.jpg)
AGUA REGENERADA: RETIRO
Superficie: 56,9 Ha. Inicio Riego 17/6/2002
![Page 12: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/12.jpg)
PLAN DE REUTILIZACIÓN DE AGUASBALDEO CON AGUA REGENERADA
![Page 13: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/13.jpg)
PLAN DE REUTILIZACIÓN DE AGUASESQUEMA DARSENA PARQUE ATENAS
![Page 14: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/14.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED CENTRO – DEPOSITOS Y DÁRSENAS
Dársena
del Parque de Atenas
![Page 15: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/15.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED CENTRO – DEPOSITOS Y DÁRSENAS
Depósito y Dársena del Parque del Oeste
![Page 16: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/16.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED CENTRO – DEPOSITOS Y DÁRSENAS
Dársenas :
Dársena Cuña Verde I Latina (1.000 m3)Dársena Cuña Verde II Latina (1.000 m3)Dársena Fuente del Berro (500 m3)Dársena Parque de Atenas (1.000 m3)Dársena Las Cruces (1.000 m3)Dársena de Entrevías (750 m3)
Depósitos :
Depósito ERAR China (6.000 m3)Depósito Emperatriz Maria de Austria (8.000 m3)Depósito Tierno Galván (7.000 m3)Depósito del Nudo de O´Donnell (7.500 m3) Depósito de la Cuña Verde Latina (2.000 m3)Depósito del Parque del Oeste (6.000 m3)
![Page 17: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/17.jpg)
Depósitos Parque Juan Carlos I
Depósito Parque Capricho
PLAN DE REUTILIZACIÓN DE AGUASRED NORTE-ESTE REJAS – DEPOSITOS Y DÁRSENAS
![Page 18: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/18.jpg)
Superficie: 160 Ha.Inicio Riego Ag. Regenerada: 24/9/2008
PLAN DE REUTILIZACIÓN DE AGUASRED NORTE-ESTE REJAS – RIEGO PARQUE JUAN CARLOS I
![Page 19: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/19.jpg)
Superficie: 129 (Parque) + 34,85 (J.Comp) Ha.Inicio Riego Ag. Regenerada: 15/6/2010
PLAN DE REUTILIZACIÓN DE AGUASRED NORTE-ESTE REJAS – PARQUE VALDEBEBAS Y URBANIZACIÓN
![Page 20: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/20.jpg)
Inicio Riego Ag. Regenerada: 28/6/2011
PLAN DE REUTILIZACIÓN DE AGUASRED NORTE-ESTE REJAS – C.GOLF OLIVAR DE LA HINOJOSA Y CIUDAD DEPORTIVA DEL REAL MADRID
Inicio Riego Ag. Regenerada: 13/9/2009
![Page 21: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/21.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED NORTE-ESTE REJAS – PLANTA TRATAMIENTO
Capacidad Diaria: 86.400 m3/día
![Page 22: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/22.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED NORTE-OESTE VIVEROS – PLANTA TRATAMIENTO
Capacidad Diaria: 31.100 m3/día
![Page 23: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/23.jpg)
PLAN DE REUTILIZACIÓN DE AGUASRED SURESTE-GAVIA – PLANTA TRATAMIENTO
Capacidad Diaria: 43.200 m3/día
![Page 24: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/24.jpg)
PLAN DE REUTILIZACIÓN DE AGUAS REGENERADASSISTEMA DE CONTROL
![Page 25: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/25.jpg)
PLAN DE REUTILIZACIÓN DE AGUASESQUEMA RED GENERAL (M 40 DEL AGUA)
![Page 26: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/26.jpg)
Datos de Interés
Longitud Red Primaria construida………..….…... 150 km.
Número Depósitos y Dársenas construidos…….. 62 ud.
Capacidad almacenamiento …...………..……. 156.300 m3
Consumo Ag. Regenerada 2013 …………………. 5,8 hm3
PLAN DE REUTILIZACIÓN DE AGUASSITUACION ACTUAL (M 40 DEL AGUA)
![Page 27: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/27.jpg)
NUEVAS ACTUACIONES Mejora y ampliación del tratamiento terciario ERAR Viveros
Qmed: 151.200 m3/d
- 4 filtros textiles - 2 líneas de ozonización - dosificación peroxido hidrógeno - 2 canales de ultravioletas
A la salida de los filtros textilesla calidad exigida será: · Huevos nematodos < 1 huevo/10 l · SS < 5 ppm · Turbidez < 10 NTU · ecoli < 2,2 ufc /100 ml
![Page 28: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/28.jpg)
NUEVAS ACTUACIONES Mejora y ampliación del tratamiento terciario ERAR La Gavia
Qmed: 86.400 m3/d
- 6 filtros textiles de disco - 2 líneas de ozonización - dosificación peroxido hidrógeno - 2 canales de ultravioletas
A la salida de los filtros textilesla calidad exigida será: · Huevos nematodos < 1 huevo/10 l · SS < 5 ppm · Turbidez < 10 NTU · ecoli < 2,2 ufc /100 ml
![Page 29: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/29.jpg)
NUEVAS ACTUACIONES Ampliación de la red de agua regenerada
- Riego del Parque forestal de Villaverde
· 2.000 m de conducciones
· 2 depósitos con capacidad para 2.000 m3
· 100 Has de zonas verdes
- Riego del Parque Juan Pablo II
· 1 depósito de 700 m3 y 1 dársena
· 2.000 m de conducciones
· 40 Has de zonas verdes
- Conexión O´Donnell Retiro
· Refuerzo riego Parque de El Retiro
·1.900 m de conducciones
· Capacidad máxima diaria: 3.500 m3
![Page 30: Side Event IMDEA_Pedro Catalinas, Madrid City Council, 14th January, UN Water Conference Zaragoza 2015](https://reader038.fdocumento.com/reader038/viewer/2022102903/55b52c43bb61eb42698b4824/html5/thumbnails/30.jpg)
MUCHAS GRACIAS( [email protected])