SIUI CTS-4959 Presentation

18
8/17/2019 SIUI CTS-4959 Presentation http://slidepdf.com/reader/full/siui-cts-4959-presentation 1/18 Ultrasonic Thickness Gauge CTS-49/59

Transcript of SIUI CTS-4959 Presentation

Page 1: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 1/18

Ultrasonic Thickness Gauge

CTS-49/59

Page 2: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 2/18

CTS-49/59

Through Coating

Auto Echo Search

Rotatable Screen Two-point Calibration

Page 3: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 3/18

Small Size, Powerful Functions

The latest ultrasonic thickness gauge

CTS-49 and CTS-59 are newly

released models by SIUI.

To keep pace with the leading

technology and the marketrequirements, CTS-49 and CTS-59

are the high-end thickness gauge

models which combine the latest

techniques, innovative design and

complete inspection requirements.

It is suitable for a wide range of

applications, including corrosion.

Page 4: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 4/18

Superior Features

Measurement range: 0.5~600mm.

Compact size and weighs only 0.6kg including battery.

5” high resolution color TFT-LCD monitor with high-brightness LED backlight

(visible under sunshine), 800x480 pixels.

Auto search function can automatically adjust the display range and the gain based on the

detected echo.

Standard (R-B1, transmission pulse to the first echo), through coating measurement (B1-B2,

or Bm-Bn) and coating measurement functions available.

One-point, Two-points and Fast zero point calibrations available.

Single and dual element probes for selection. CTS-59 can support dialogue thickness gauge

 probe to realize probe auto-recognition function, which can reduce display measurement dataerror.

A/B scan functions

Page 5: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 5/18

Portrait and Landscape Screen

Auto Gravity sensing Design

Portrait

Landscape

Page 6: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 6/18

Multiple connectors

 ——MicroSD card port

 ——I/O port (Reserved)

 ——MiniUSB port

 ——DC power input port

Page 7: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 7/18

DataView Software

A Microsoft Windows based

application is used to acquire, create,

 print and manage data on the CTS-

49/59.

Measurement data will be displayed

in color grid view for better data

analysis.

Page 8: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 8/18

Advanced Functions

COATING Measurement

MULTI-Layers Measurement

V-PATH

TDG Function (Time Depth Gain) TEMP Function (Temperature Compensation)

B scan

Page 9: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 9/18

COAT Measurement

Under Thru-Coating mode, after setting

the painting velocity, through-coating

thickness and coating thickness can bedisplayed at the same time.

Through Coating Thickness

Coating Thickness

Page 10: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 10/18

MULTI-Layers Measurement

For work piece with multi-layers

materials and tight bonding between each

layer, thickness measurement of eachlayer with known velocities as well as the

total thickness, can be displayed.

Page 11: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 11/18

V-PATH

The system default sets a group of V-

PATH calibration curve for all compatible

dual element probes. Users can make agroup of V-PATH curve corresponding to

the probes in use.

Page 12: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 12/18

TDG Function (Time Depth Gain)

It can be used for compenstating wave

amplitude lose caused by transmitting

sound path.

Page 13: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 13/18

TEMP Function

(Temperature compensation)

Generally the velocity of solid material

will reduce as its temperature increases.

So when there is temperature difference between the calibration test block and

the detected work piece, TEMP

function can be used for temperature

compensation.

Page 14: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 14/18

B scan

B scan function is especially

good for corrosionapplication.

Page 15: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 15/18

Specifications of CTS-49/59

RF /Full/Positive/NegativeA -scan Rectification

Off/On: With this function activated, proper display range and gain can be adjusted automatically based on the measured

waveform echo, which improves measurement efficiency.Auto Search

0-110dB manually adjustable;

Auto (for auto-search)Gain

400~15000 m/sVelocity Range

High temperature

7.5MHz, single crystal delay type

Smart-dialog 7.5MHz dual crystal7.5MHz dual crystal

Smart-dialog 5MHz dual crystal5MHz dual crystal

Smart-dialog 2MHz dual crystal2MHz dual crystal

Compatible Probes

0.01mm / 0.1mm (0.001 in / 0.01 in)Display Resolution

0.5~600mm (subject to probe, material, temperature and selected configuration)Measurement Range

With known coating velocity, coating thickness can be

measured. __ 

Standard (R-B1, transmit pulse to the first echo);Through coating measurement (B1-B2, or Bm-Bn);

All measurements using Zero Crossing.Measurement Mode

800×480 pixels, 5” high-brightness color TFT-LCD monitor with high resolution LED backlight (visible under sunshine)Display Screen

CTS-59CTS-49Model

Page 16: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 16/18

Specifications of CTS-49/59

Up to 20,000 sets of measurement data (including

measurement value, velocity and 5 file formats for

application);

Up to 100 sets of parameter data (such as measurement value

and system setting)

Up to 10,000 sets of measurement data (including

measurement value, velocity and 3 file formats for

application);

Up to 100 sets of parameter data (such as measurement

value and system setting)

Storage Function

B-scan —— B-scan

Portrait/Landscape screen/auto (gravity-sensing auto switch), suitable for left/ right handednessVertical/Horizontal Screen

Velocity dynamic measurement, measurement value over-limit symbol, sound alarm and freeze function.Other Functions

Standard /Simple menu measurement interfaceInterface Mode

Standard/ minimum/ maximum/ average/ differenceMeasurement Function

a. Fast zero point calibration with the built-in test block.

 b.User-defined calibration (one-point/two-point calibration)Calibration

With a configured probe, it can measure steel tube with diameter not less than 20mm and wall thickness not less than

2.0mm

Tube Wall Thickness

Measurement

0.80mm ~ 9.99mm:± 0.05mm

10.00mm ~ 99.99mm:± (1‰H + 0.04)mm100.0mm ~ 400.0mm:± 3‰H mm

【 Note】: H is thickness of the detected material.

Display Error (With configured probe)

4/8/16/32Measurement times

 Negative square wave transmission, with pulse-width and voltage auto fits the probePulser 

Page 17: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 17/18

Specifications of CTS-49/59

COAT Measurement Function, MULTI Layers Measurement

Function, V-PATH Function, TDG Function and TEMP

Function

 —— Software

MiniUSB, micro SD card holder, DC-IN (DC12V input), LEMO 00 compliant (T/R)System Port

Approx. 600g with batteryWeight

105 mm× 180 mm× 42 mm (WxHxL)Dimension

a. With battery in the system: approx. 6 hours

 b. With configured external charger: approx. 3 hours

a. With battery in the system: approx. 6 hours

 b. With external charger: approx. 3 hours (option)Battery Charge Time

a. DC 12V power adapter  b.≥6 hours’ operation with 7.4V rechargeable lithium battery set

Power Supply

-10~45℃Operation Temperature

Off/2/5/10/20/30 minutes for selectionAuto Shutoff 

English/Chinese/Spanish/German/Japanese/Russian/Polish/Portuguese/FrenchLanguage

inch/mmMeasure Unit

The data can be stored to a micro SD card and transferred to a PC via a card reader;

It can also be transferred to a PC via the miniUSB port.Data Transmission

Page 18: SIUI CTS-4959 Presentation

8/17/2019 SIUI CTS-4959 Presentation

http://slidepdf.com/reader/full/siui-cts-4959-presentation 18/18