SPECIFICATION FEATURES
Construction
HOUSING: Heavy-duty, formedsteel housing with an open airballast for cooler operation isfinished in a white polyester
powder coat.
Electr ica l
BALLAST: High power factor ballastwith class H insulation. Minimumstarting temperature is -40C(-40F) for HPS and -30C (-20F) forMH. SOCKET: Mogul-baseporcelain socket standard for HPS.
For Metal Halide, protected socketstandard, for use with "0" (Open)rated protected Metal Halide lampsonly.
Optica l
SEALED OPTICS: Enclosed andgasketed optics seal out dirt andother contaminants. REFLECTOR:Computer designed, facetedreflector provides maximumphotometric performance. HANDS-FREE RELAMPING: Trunk latchessecure the reflector to the housing,
allowing toolless entry, whileinternal hangers holdreflector/refractor for hands-freerelamping. LENS: 100% virgin UVstabilized acrylic refractor.
Mounting
Easy slide-on die-cast aluminummounting box with tapped openingfor 3/4" conduit.
ENTERPRISE
70 - 4
High Pressure So
Pulse Start Metal H
Metal H
ALUMINUM LOW
The Enterprise 22 industrial low-bay luminaire combines a round, facetedreflector with an injection-molded lens to provide an efficient,symmetrical beam pattern. U.L. listed and labeled for damp location. CSACertified. The Enterprise 22 combines durable construction with preciseoptics for mounting heights below 20'. Perfect for warehouses, foundries,gyms, assembly areas, food processing plants and hangars.
DESCRIPTION
SYS
T
CERT
26
[660mm]
22 [559mm]
DIMENSIONS
ADH0
2015-12-021
Lumar
7/26/2019 Especificacin Bombilla Lumark
2/3
PHOTOMETRICS
EP
ENTERPRISE 22
ADH082409
2015-12-0210:26:0
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 SouthPeachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
7/26/2019 Especificacin Bombilla Lumark
3/3
VOLTAGE CHART
120/208/240/277V (wired 277V)
120/277/347V (wired 347V)
120/208/240/277/480V (wired 277V)
MT= Multi-Tap
TT= Triple-Tap
5T= 5-Tap8
Pulse Start Metal Halide (MP) 70, 100, 175, 200, 250, 320, 350, 400, 450W
Metal Halide (MH) 175, 250, 400W
High Pressure Sodium (HP) 70, 100, 150, 250, 400W
LAMP TYPE WATTAGE
SeriesF=Enterprise
Lamp TypeS=High Pressure Sodium
M=Metal Halide
P=Pulse Start Metal Halide
Lamp Wattage25=250W32=320W
40=400W35=350W
40Q=400W and Quartz Restrike258=250W (Canada, Triple-Tap Ballast)408=400W (Canada, Triple-Tap Ballast)
S tock Sa m ple # : F S 2 5 - NL
NOTES:
Options not available with stock products.Order Accessories as separate items forfield installation. Refer to standard orderinginformation to add options and accessories.
F
STOCK SAMPLE NUMBER
ADH08240
2015-12-0210:26:0
EP
ENTERPRISE 2ORDERING INFORMATION
Sample Number: MPEP-R22-250-MT-Q
Voltage4
120V 120V=
208V 208V=
240V 240V=
277V 277V=
347V 347V=
480V 480V=
MT Multi-Tap,wired277V
5
TT Triple-Tap,wired347V
6
5T 5-Tap7
Lamp
Wattage
MP
100 100W=
175 175W=
250 250W=
320 320W=
400 400WMH 2
175 175W
250 250W
400 400W
HP
100 100W
250 250W
400 400W
Accessories 14
C3 3'Cord-NoPlug-RequiresFH-1,FL-1,orSHK
9=
PC3 3'CordwithNEMAPlug-(120V-L5,208V-L6-15P,347V-L37-20Pand480V-L8-20P)Othercordlengthsareavailablebyspecifyinglength(PC6for6'cord).RequiresFH-1orFL-1,orSHK.UsewithTPPH-NEMA.SpecifyVoltage.
9=
PHC PowerHookCordandNon-NEMAplug
configuration.MustbeusedwithFL-1andTPPH(Thru-WayPendantPowerHook)
PHC-NEMA PowerCordandNEMAplug-18"PowerCordand20AmpNEMAplugconfiguration.MustbeusedwithFL-1andTPPH-NEMA(Thru-WayPendantPowerHook)
WG22/EP WireGuard
MBT TwinMountBracket(Fixturesmustbesamevoltageandwithouthooks,loopsorplugs.)
TPPH Thru-WayPendantPowerHook.RequiresFL-1andPHC.SpecifyVoltage.
TPPH-F Thru-WayPendantPowerHookSingleFuse,120,277or347Volt.RequiresFL-1andPHC.SpecifyVoltage.
=
TPPH-F2 Thru-WayPendantPowerHook-DoubleFused,208,240,or480Volt.RequiresFL-1andPHC.SpecifyVoltage.
=
TPPH-F-QD Thru-WayPendantPowerHookSingleFuse,QuickDisconnect.RequiresFL-1andPHC.SpecifyVoltage(120,277,or347V)
TPPH-F2-QDThru-WayPendantPowerHookDoubleFuse,QuickDisconnect.RequiresFL-1andPHC.SpecifyVoltage(208,240,or480V)
=
TPPH-NEMA Thru-WayPendantPowerHook.RequiresFL-1andPHC-XXXV-NEMA.(Specify
=
FH-1 FixtureHook=
FL-1 FixtureLoop=
SHK HookwithSafetyScrew=
TWMBS Thru-WayMountingBox15=
Options
C3 3'Cordwithnoplug(SpecifyVoltage)9=
PC3 3'CordwithNEMAPlug(120V-L5-15P,208V-L6-15P,347V-L37-20P,AND480V-L8-20P)Othercordlengthsareavailablebyspecifyinglength(PC6for6'Cord)RequiresFH-1orFL-1,orSHK.Example:PC3-120VUsewithTPPH-NEMA.SpecifyVoltage.
9=
PHC PowerCordandPlug(18"PowerCordandNon-NEMAplugconfiguration.MustbeusedwithFL-1andTPPH(Thru-WayPendantPowerHook).Mustspecifysinglevoltage.
=
PHC-NEMA PowerCordandNEMAPlug(18"PowerCordand20AMPNEMAplugconfiguration).MustbeusedwithFL-1andTPPH-NEMA(Thru-WayPendantPowerHook).
FH-1 Die-castAluminumFixtureHook(with3/4"threadsforeasyinstallation)=
FL-1 MalleableIronPlatedFixtureLoop(with3/4"threadsforeasyinstallation)
SHK Die-castAluminumFixtureHook(withsafetyscrewand3/4"threadsforeasyinstallation)
=
F1 SingleFuse(120,277or347Vonly)
F2 DoubleFuse(208,240or480Vonly)=
SCF 3'AircraftSafetyCablesecuresHousingtoCeiling(Alternativelengthsavailable.Example:SCF6=6'Cable)
=
Q QuartzRestrike(HotStrikeOnly)=
EM QuartzRestrikewith''DelayRelay''(Quartzlampstrikesatbothhotandcoldstarts)=
EM/SC EmergencySeparateCircuit10=
L/TCB LessTopConnectorBox(Housingshippedlesstopconnectorbox.(SpecifywhenusingTWMBSaccessory)
=
LL LampIncluded11=
SCR AircraftSafetyCable-HousingtoReflector=
W/MWS MWSIndustrialcomponentsattachedtothefixtureatthefactory.(Standardcordlengthis3ft.6ft.and11ft.alsoavailable.PleaserefertoMWSModularWiringSystemsectionfor
additionalinformation.
=
HC LumaWattFixtureControlModule(Lowvoltageleadspulledoutoftopconnectionboxforareasrequiringallwiringtobeinstalledinconduit)
12, 13=
HL LumaWattFixtureControlModule(Allowslowvoltagecontrolwiretobedaisy-chainedbetweenfixturesoutsideACconduitrunsimilartolowvoltageintercom's,firealarmsandphonesystems)
13=
QLL QuartzLampIncluded(LampisCooperdesignatedproductbasedonluminairerequirements.Lampisshippedseparatefromluminaireunlessotherewisenoted)
=
FILT SinteredBronzefilter(Sinteredbronzefilterpreventstheentranceofcontaminants)
=
Reflector
Diameter
R22 22''ReflectorDiameter=
Lamp Type
MP PulseStartMetalHalide
1=
MH MetalHalide1, 2=
HP HighPressureSodium=
Reflector Type
__ Acrylic=
PL Polycarbonate3=Series
EP Enterprise
Socket
OR OpenRatedSocketforMetalHalideLamps
8
__ NonApplicable(HPSorNotcompatiblewithORSocket)
1 Open Rated socket and lamp must be used.Notes:
2MH available in non-U.S. markets only.
3 Not recommended for use with Metal Halide lamps due to rapid yellowing typical ofpolycarbonate material.
4 Products also available in non-US voltages and 50HZ for international markets. Consult yourCooper Representative for availabiltiy and ordering information. 88% Efficient EISA CompliantMP Fixtures not available in 347V and TT Voltages.
5 Multi-Tap ballast 120/208/240/277V wired 277V.
6 Triple-Tap ballast 120/277/347V wired 347V.
7 5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISACompliant MP fixtures not available in 5-Tap Voltages.
8 Not applicable for HPS.
9 Requires FH-1or FL-1or SHK.
10 Not available with HL or HC options.
11 Lamp is shipped separately.
12 Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order.
13 30 second time delay when switching from bright to dim. Consult individual lampmanufacturers recommendations for compatible lamps. For use with CWA ballast only.
14 Order separately.
15 Specify L/TCB when using thru-way mounting box (TWMBS) accessory.
Specifications anddimensions subject to
change without notice.
Eaton
1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800
www.eaton.com/lighting