INSPECCIONES DE EXTINTORESCOD

FECHA

VERSION 00

LUGAR: ENATIN S.A. - EXTINTORES OPERATIVOS - NAVES 1, 2, 3

SUPERVISOR / TECNICO: ERICK MICHAEL TAPIA LUZARDO FECHA: 8/20/2014

AREA UBICACIÓN TIPO CAPACIDAD CODIGO FECHA DE CARGA FECHA DE RECARGA

SE

ÑA

LIZ

AD

O

DE

MA

RC

AD

O

SE

LLO

DE

SE

GU

RID

AD

MA

NG

UE

RA

DE

BO

QU

ILLA

MA

NO

ME

TR

O

PR

ES

ION

(P

SI)

CA

LCO

MA

NIA

MA

NIJ

A

ES

TA

DO

GE

NE

RA

L

ALT

UR

A A

DE

CU

AD

A

DE

SC

AR

GA

DO

OB

ST

AC

ULI

ZA

DO

OT

RO

S

OBSERVACIONES

1 ENTRADA PQS 20 LBS 576 Jan-14 Jan-15 C C C NC C C NA C C C C NA NA NA

2 COMEDOR PQS 20 LBS 570 May-14 May-15 C NC C C C C NA C C C C NA NA NA

3 BODEGA PINTURA PQS 20 LBS 591 May-14 May-15 C C C C C C NA C C C C NA NA NA

4 TALLER ELECTRICO PQS 20 LBS 574 Oct-13 Oct-14 C C C NC C C NA NC C NC C NA NA NA

5 BODEGA PQS 20 LBS Feb-13 Feb-14 C C C C C C NC C C NC C NA NA NA CADUCADO - MANDADO A PINTAR

6 GRANALLA PQS 20 LBS 581 Oct-13 Oct-14 C C C NC C C NA C C C C NA NA NA POR CADUCAR

7 CUARTO ELECTRICO CO2 15 LBS 768 May-14 May-15 C C C C C NA NA C C C C NA NA NA

8 BODEGA - INTERIOR PQS 10 LBS 561 Jan-14 Jan-15 C C C C C C NA C C C C NA NA NA

9 BODEGA ALMACENADO CO2 20 LBS 580 May-14 May-15 NA NA C C C NA C C C C NA NA NA NA ALMACENADO EN BODEGA

10 BODEGA ALMACENADO PQS 5 LBS S/N Aug-14 Aug-15 NA NA C C C C C C C C NA NA NA NA ALMACENADO EN BODEGA

11 BODEGA ALMACENADO PQS 5 LBS S/N Aug-14 Aug-15 NA NA C C C C C C C C NA NA NA NA ALMACENADO EN BODEGA

12 BODEGA ALMACENADO CO2 10 LBS 565 May-14 May-15 NA NA C C C NA C C C C NA NA NA NA ALMACENADO EN BODEGA

13 BODEGA ALMACENADO PQS 10 LBS 569 May-14 May-15 NA NA C C C C C C C C NA NA NA NA ALMACENADO EN BODEGA

14 OFICINAS - PROYECTO CO2 5 LBS 554 Aug-13 Aug-14 C NC C C C NA NA C C C C NA NA NA POR CADUCAR

15 OFICINAS - PROYECTO CO2 5 LBS 551 Aug-13 Aug-14 C NC C C C NA NA C C C C NA NA NA POR CADUCAR

16 OFICINAS - ADMIN CO2 5 LBS 550 Aug-13 Aug-14 C NC C NC C NA NA C C C NC NA NA NA POR CADUCAR

17 OFICINAS - ADMIN PQS 5 LBS 552 Aug-13 Aug-14 NC NC C C NC C NA C C C NC NA NA NA POR CADUCAR - HYUNTA

18 AREA DE CILINDROS PQS 20 LBS 586 Feb-14 Feb-15 C C C C C C C C C C C NA NC NA

19 AREA DE PINTURA PQS 20 LBS 592 May-14 May-15 NC NC C NC C C NA C C C C NA NA NA

20 AREA PULIDORES PQS 20 LBS 582 May-14 May-15 C C C C C C NA C C C C NA NC NA

21 PANTOGRAFO PQS 20 LBS 593 Oct-13 Oct-14 C C C C C C NA C C C C NA NA NA POR CADUCAR

22 ROLADORA PQS 20 LBS 571 Aug-14 Aug-15 C C C NC C NC NC C C NC C NC NA NA PRESION BAJA

23 AREA GRUAS PQS 20 LBS 772 Jan-14 Jan-15 C C C C C C C C C C C NA NC NA

24 3 AREA DE ALMACENACIENTO NAVE PQS 20 LBS 579 May-14 May-15 C C C C C C C C C C C NA NA NA

254

CAMION PQS 20 LBS Aug-13 Aug-14 NA NA C C C C C C C C NA NA NA NA

26 GRUA C. MUÑOZ PQS 20 LBS 587 Jan-14 Jan-15 NA NA C C C C C C C C NA NA NA NA

OBSERVACIONES: Los equipos contra incendio como minimo cada año se les debe realizar recarga de acuerdo al agente de extincion presente ABC - PQSM Los equipos contra incendio como minimo cada 5 años se les debe realizar recarga de acuerdo al agente de presente Agente LimpioLos equipos contra incendio CO2 se debe realizar la verificacion de su carga de forma periodica, y como minimo cada año realizar mantenimientoLa demarcacion se realiza empleando pintura de color amarillo y rojo

LEYENDAS:CUMPLE: C NO CUMPLE: N/C NO APLICA: N/A

INSPECCIONADO POR: REVISADO POR:

SUPERVISOR DE SST RESPONSABLE DE SST

Nº Ext

PA

SA

DO

R D

E

SE

GU

RID

AD

NAVE 1

NAVE 2